CSV injection in Hitachi Energy MicroSCADA SYS600
Key facts
- Attack vector
- Local
- Privileges required
- None
- User interaction
- Active
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- —
- Confidentiality · integrity · availability
- Low · Low · None
- Fix status
- No fix listed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA.
Summary
A CSV injection vulnerability exists in SYS600. Injected malicious formulas can add or modify data to the spreadsheet, insert links, exfiltrate data, and in some cases, depending on how the user has their environment configured, execute malicious code on the user’s machine. To exploit this issue attackers would need a way to create arbitrary log messages. This could be achieved through normal functionality via SCIL scripts, a log injection vulnerability, or via the SYS600 broker. This vulnerability affects all Windows users regardless of their privilege level who can run the Notify service and export the log.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Hitachi Energy | MicroSCADA SYS600 | 10.0 – 10.7 | — | No fix listed | CNA |
- MicroSCADA SYS600 VendorHitachi Energy Affected 10.0 – 10.7 Fixed in — No fix listed CNA
CPE configurations NVD · 1
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:* | 10.0 – 10.7 | Vulnerable | Hitachi Energy |
- cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:* Versions 10.0 – 10.7 Vulnerable ·Hitachi Energy
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2026-9852
- 2026-10-03 Alias added: GHSA-5ph9-h7vg-rh4m
References
More Hitachi Energy Microscada X Sys600 vulnerabilities
- TI-2024-07362 The product exposes a service that is intended for local only to all network interfaces without any authentication. CVSS 3.1CRITICAL 9.8
- TI-2024-03713 Path traversal in Hitachi Energy MicroSCADA X SYS600 CVSS 3.1CRITICAL 9.9
- TI-2024-04530 A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. CVSS 3.1CRITICAL 9.9
- TI-2022-12271 Improper input validation in Hitachi Energy MicroSCADA X SYS600 CVSS 3.1HIGH 7.5
- TI-2022-11954 Improper input validation in Hitachi Energy MicroSCADA X SYS600 CVSS 3.1HIGH 7.5
- TI-2022-02102 A vulnerability exists in the ICCP stack of the affected SYS600 versions due to… CVSS 3.1HIGH 7.5
Sources
- CVE-2026-9852 · CVE Program
- CVE-2026-9852 · NVD
- FIRST EPSS
- GHSA-5ph9-h7vg-rh4m · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences