TI-2019-15767 Aliases CVE-2019-25716GHSA-x6h5-p8qf-9j76

Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet

Priority LOW 31CWE-15Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
—
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA.

Summary

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00413 35th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
DrägerInfinity DeltaInfinity Delta—No fix listedCNA
DrägerInfinity Delta XLInfinity Delta XL—No fix listedCNA
DrägerInfinity KappaInfinity Kappa—No fix listedCNA
  • Infinity Delta VendorDräger Affected Infinity Delta Fixed in — No fix listed CNA
  • Infinity Delta XL VendorDräger Affected Infinity Delta XL Fixed in — No fix listed CNA
  • Infinity Kappa VendorDräger Affected Infinity Kappa Fixed in — No fix listed CNA

CPE configurations NVD · 6

CPEVersionsRoleVendor
cpe:2.3:o:draeger:infinity_delta_firmware:*:*:*:*:*:*:*:*all versionsVulnerableDräger
cpe:2.3:h:draeger:infinity_delta:-:*:*:*:*:*:*:*not specified by NVDRunning onDräger
cpe:2.3:o:draeger:delta_xl_firmware:*:*:*:*:*:*:*:*all versionsVulnerableDräger
cpe:2.3:h:draeger:delta_xl:-:*:*:*:*:*:*:*not specified by NVDRunning onDräger
cpe:2.3:o:draeger:kappa_firmware:*:*:*:*:*:*:*:*all versionsVulnerableDräger
cpe:2.3:h:draeger:kappa:-:*:*:*:*:*:*:*not specified by NVDRunning onDräger
  • cpe:2.3:o:draeger:infinity_delta_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Dräger
  • cpe:2.3:h:draeger:infinity_delta:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Dräger
  • cpe:2.3:o:draeger:delta_xl_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Dräger
  • cpe:2.3:h:draeger:delta_xl:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Dräger
  • cpe:2.3:o:draeger:kappa_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Dräger
  • cpe:2.3:h:draeger:kappa:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Dräger

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2019-25716
  2. 2026-10-03 Alias added: GHSA-x6h5-p8qf-9j76

References

  • TI-2018-13476 Improper privilege management in ICS-CERT Dräger Infinity Delta CVSS 3.0HIGH 7.8
  • TI-2018-13478 Sensitive information in log files in ICS-CERT Dräger Infinity Delta CVSS 3.0MEDIUM 6.5
  • TI-2018-13474 Improper input validation in ICS-CERT Dräger Infinity Delta CVSS 3.0MEDIUM 6.5
  • TI-2019-15768 Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure CVSS 4.0MEDIUM 5.3

Sources