Draeger X-Dock Firmware before 03.00.13 has Hard-Coded Credentials, leading to remote…
Draeger X-Dock Firmware before 03.00.13 has Hard-Coded Credentials, leading to remote code execution by an authenticated attacker.
No Dräger vulnerabilities are listed in CISA KEV.
23 records
Draeger X-Dock Firmware before 03.00.13 has Hard-Coded Credentials, leading to remote code execution by an authenticated attacker.
Dräger Core 1.0.5 and Dräger M540 Converter Service 1.0.9 contain a denial of service vulnerability that allows network-adjacent attackers to trigger high CPU load by sending specially crafted, unencrypted SDC messages d…
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower (with VG4.2 partially affected) contain a network message handling vulnerability that allows remote att…
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers…
Draeger X-Dock Firmware before 03.00.13 has Active Debug Code on a debug port, leading to remote code execution by an authenticated attacker.
Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction.
A low privileged local attacker can interact with the affected service although user-interaction should not be allowed.
Dräger Protector Software prior to version 6.4.2 contains a local privilege escalation vulnerability due to insecure file system permissions that allows local attackers to execute arbitrary code with elevated privileges.
Dräger Protector Software prior to version 6.4.2 contains a local privilege escalation vulnerability due to insecure file system permissions that allows local attackers to execute arbitrary code with elevated privileges.
Dräger CC-Vision Basic before 7.5.3 and Dräger CC-Vision E-Cal before 7.2.5.0 contain an out-of-bounds write vulnerability when loading .gdt files.
Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions.
Dräger Zeus Infinity Empowered (Zeus IE) and Zeus RS C500 anesthesia workstations contain a local security vulnerability that allows unauthorized individuals with physical access to compromise software integrity via USB…
Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to co…
Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending…
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet.
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeated…
Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by…
Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions.
Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions.
Dräger Atlan A350 versions 1.00 up to and including 1.01 contains an improper input handling vulnerability that allows attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant data thr…
Dräger Perseus A500 software versions 2.00 through 2.02 contains an improper input handling vulnerability that allows external attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant…
A low privileged local attacker can abuse the affected service by using a hardcoded cryptographic key.
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection.