Hard-coded credentials in Baxter Sigma Spectrum Infusion Pumps

Priority MEDIUM 45CWE-259Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-259.

Summary

The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials.

Why it matters now

EPSS 0.01676 77th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—Baxter Sigma Spectrum Infusion PumpsSigma Spectrum v6.x model 35700BAX,Spectrum v8.x model 35700BAX2,Sigma Spectrum v6.x with Wireless Battery Module (WBM) v9,v11,v13,v14,v15,v16,v20D29,v20D30,v20D31,v22D24, Spectrum v8.x w/WBM v17,v20D29,v20D30,v20D31,v22D24,Spectrum WBM v17,v20D29,v20D30,v20D31,v22D24,Spectrum LVP v8.x with WBM v17, v20D29,v20D30,v20D31,and v22D24—No fix listedCNA
  • Baxter Sigma Spectrum Infusion Pumps Vendor— Affected Sigma Spectrum v6.x model 35700BAX,Spectrum v8.x model 35700BAX2,Sigma Spectrum v6.x with Wireless Battery Module (WBM) v9,v11,v13,v14,v15,v16,v20D29,v20D30,v20D31,v22D24, Spectrum v8.x w/WBM v17,v20D29,v20D30,v20D31,v22D24,Spectrum WBM v17,v20D29,v20D30,v20D31,v22D24,Spectrum LVP v8.x with WBM v17, v20D29,v20D30,v20D31,and v22D24 Fixed in — No fix listed CNA

CPE configurations NVD · 7

CPEVersionsRoleVendor
cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:8.0:*:*:*:*:*:*:*8.0VulnerableBaxter
cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:*not specified by NVDRunning onBaxter
cpe:2.3:h:baxter:wireless_battery_module:17:*:*:*:*:*:*:*17Running onBaxter
cpe:2.3:h:baxter:wireless_battery_module:20d29:*:*:*:*:*:*:*20d29Running onBaxter
cpe:2.3:h:baxter:wireless_battery_module:20d30:*:*:*:*:*:*:*20d30Running onBaxter
cpe:2.3:h:baxter:wireless_battery_module:20d31:*:*:*:*:*:*:*20d31Running onBaxter
cpe:2.3:h:baxter:wireless_battery_module:22d24:*:*:*:*:*:*:*22d24Running onBaxter
  • cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:8.0:*:*:*:*:*:*:* Versions 8.0 Vulnerable ·Baxter
  • cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Baxter
  • cpe:2.3:h:baxter:wireless_battery_module:17:*:*:*:*:*:*:* Versions 17 Running on ·Baxter
  • cpe:2.3:h:baxter:wireless_battery_module:20d29:*:*:*:*:*:*:* Versions 20d29 Running on ·Baxter
  • cpe:2.3:h:baxter:wireless_battery_module:20d30:*:*:*:*:*:*:* Versions 20d30 Running on ·Baxter
  • cpe:2.3:h:baxter:wireless_battery_module:20d31:*:*:*:*:*:*:* Versions 20d31 Running on ·Baxter
  • cpe:2.3:h:baxter:wireless_battery_module:22d24:*:*:*:*:*:*:* Versions 22d24 Running on ·Baxter

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2020-12047
  2. 2026-10-03 Alias added: GHSA-j5f9-r6jx-6c24

References

  • TI-2014-04431 Improper authentication in Baxter SIGMA Spectrum Infusion System CVSS 3.0CRITICAL 9.8
  • TI-2020-09702 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for… CVSS 3.1CRITICAL 9.8
  • TI-2014-04432 Cleartext storage of sensitive information in Baxter SIGMA Spectrum Infusion System CVSS 3.0CRITICAL 9.8
  • TI-2020-09703 Hard-coded credentials in Baxter Sigma Spectrum Infusion Pumps CVSS 3.1CRITICAL 9.8
  • TI-2014-04433 Hard-coded credentials in Baxter SIGMA Spectrum Infusion System CVSS 3.0CRITICAL 9.8
  • TI-2020-09699 Cleartext transmission of sensitive information in Baxter Sigma Spectrum Infusion Pumps CVSS 3.1CRITICAL 9.8
See all 9 →

Sources