Philips Patient Monitoring Devices Exposure of Resource to Wrong Sphere

Priority LOW 30CWE-668Published · Updated

Key facts

Attack vector
Physical
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.

Why it matters now

EPSS 0.00371 31st percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
PhilipsPatient Information Center iX (PICiX)B.02; C.02; C.03—No fix listedCNA
  • Patient Information Center iX (PICiX) VendorPhilips Affected B.02; C.02; C.03 Fixed in — No fix listed CNA

CPE configurations NVD · 3

CPEVersionsRoleVendor
cpe:2.3:a:philips:patient_information_center_ix:b.02:*:*:*:*:*:*:*b.02VulnerablePhilips
cpe:2.3:a:philips:patient_information_center_ix:c.02:*:*:*:*:*:*:*c.02VulnerablePhilips
cpe:2.3:a:philips:patient_information_center_ix:c.03:*:*:*:*:*:*:*c.03VulnerablePhilips
  • cpe:2.3:a:philips:patient_information_center_ix:b.02:*:*:*:*:*:*:* Versions b.02 Vulnerable ·Philips
  • cpe:2.3:a:philips:patient_information_center_ix:c.02:*:*:*:*:*:*:* Versions c.02 Vulnerable ·Philips
  • cpe:2.3:a:philips:patient_information_center_ix:c.03:*:*:*:*:*:*:* Versions c.03 Vulnerable ·Philips

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2020-16212
  2. 2026-10-03 Alias added: GHSA-33r4-hmp8-j73x

References

  • TI-2020-12751 Philips Patient Monitoring Devices Improper Authentication CVSS 3.1HIGH 8.8
  • TI-2020-12753 Philips Patient Monitoring Devices Improper Handling of Length Parameter Inconsistency CVSS 3.1MEDIUM 6.5
  • TI-2020-12745 Philips Patient Monitoring Devices Improper Input Validation CVSS 3.1MEDIUM 6.5
  • TI-2021-19438 Philips Patient Information Center iX (PIC iX) and Efficia CM Series Improper Input Validation CVSS 3.1MEDIUM 6.5
  • TI-2020-12757 Philips Patient Monitoring Devices Improper Check for Certificate Revocation CVSS 3.1MEDIUM 6.4
  • TI-2021-19440 Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of a Broken or Risky Cryptographic Algorithm CVSS 3.1MEDIUM 6.5
See all 10 →

Sources