TI-2021-19438 Aliases CVE-2021-43548GHSA-vqqw-576h-989f

Philips Patient Information Center iX (PIC iX) and Efficia CM Series Improper Input Validation

Priority LOW 29CWE-20Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA.

Summary

Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.

Why it matters now

EPSS 0.00389 33rd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
PhilipsPatient Information Center iX (PIC iX)C.02; C.03—No fix listedCNA
  • Patient Information Center iX (PIC iX) VendorPhilips Affected C.02; C.03 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:philips:patient_information_center_ix:c.02:*:*:*:*:*:*:*c.02VulnerablePhilips
cpe:2.3:a:philips:patient_information_center_ix:c.03:*:*:*:*:*:*:*c.03VulnerablePhilips
  • cpe:2.3:a:philips:patient_information_center_ix:c.02:*:*:*:*:*:*:* Versions c.02 Vulnerable ·Philips
  • cpe:2.3:a:philips:patient_information_center_ix:c.03:*:*:*:*:*:*:* Versions c.03 Vulnerable ·Philips

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2021-43548
  2. 2026-10-03 Alias added: GHSA-vqqw-576h-989f

References

  • TI-2020-12751 Philips Patient Monitoring Devices Improper Authentication CVSS 3.1HIGH 8.8
  • TI-2020-12753 Philips Patient Monitoring Devices Improper Handling of Length Parameter Inconsistency CVSS 3.1MEDIUM 6.5
  • TI-2020-12745 Philips Patient Monitoring Devices Improper Input Validation CVSS 3.1MEDIUM 6.5
  • TI-2020-12741 Philips Patient Monitoring Devices Exposure of Resource to Wrong Sphere CVSS 3.1MEDIUM 6.8
  • TI-2020-12757 Philips Patient Monitoring Devices Improper Check for Certificate Revocation CVSS 3.1MEDIUM 6.4
  • TI-2021-19440 Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of a Broken or Risky Cryptographic Algorithm CVSS 3.1MEDIUM 6.5