Philips Patient Monitoring Devices Improper Authentication
Priority LOW 39CWE-287Published · Updated
Key facts
- Attack vector
- Adjacent network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Security bypass
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-287.
Summary
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
Why it matters now
EPSS 0.00549 46th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Philips | Patient Information Center iX (PICiX) | B.02; C.02; C.03 | — | No fix listed | CNA |
| Philips | PerformanceBridge Focal Point | A.01 | — | No fix listed | CNA |
- Patient Information Center iX (PICiX) VendorPhilips Affected B.02; C.02; C.03 Fixed in — No fix listed CNA
- PerformanceBridge Focal Point VendorPhilips Affected A.01 Fixed in — No fix listed CNA
CPE configurations NVD · 4
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:philips:patient_information_center_ix:b.02:*:*:*:*:*:*:* | b.02 | Vulnerable | Philips |
| cpe:2.3:a:philips:patient_information_center_ix:c.02:*:*:*:*:*:*:* | c.02 | Vulnerable | Philips |
| cpe:2.3:a:philips:patient_information_center_ix:c.03:*:*:*:*:*:*:* | c.03 | Vulnerable | Philips |
| cpe:2.3:a:philips:performancebridge_focal_point:a.01:*:*:*:*:*:*:* | a.01 | Vulnerable | Philips |
- cpe:2.3:a:philips:patient_information_center_ix:b.02:*:*:*:*:*:*:* Versions b.02 Vulnerable ·Philips
- cpe:2.3:a:philips:patient_information_center_ix:c.02:*:*:*:*:*:*:* Versions c.02 Vulnerable ·Philips
- cpe:2.3:a:philips:patient_information_center_ix:c.03:*:*:*:*:*:*:* Versions c.03 Vulnerable ·Philips
- cpe:2.3:a:philips:performancebridge_focal_point:a.01:*:*:*:*:*:*:* Versions a.01 Vulnerable ·Philips
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2020-16222
- 2026-10-03 Alias added: GHSA-82hx-cp56-ffj8
References
More Philips Patient Information Center Ix vulnerabilities
- TI-2020-12753 Philips Patient Monitoring Devices Improper Handling of Length Parameter Inconsistency CVSS 3.1MEDIUM 6.5
- TI-2020-12745 Philips Patient Monitoring Devices Improper Input Validation CVSS 3.1MEDIUM 6.5
- TI-2020-12741 Philips Patient Monitoring Devices Exposure of Resource to Wrong Sphere CVSS 3.1MEDIUM 6.8
- TI-2021-19438 Philips Patient Information Center iX (PIC iX) and Efficia CM Series Improper Input Validation CVSS 3.1MEDIUM 6.5
- TI-2020-12757 Philips Patient Monitoring Devices Improper Check for Certificate Revocation CVSS 3.1MEDIUM 6.4
- TI-2021-19440 Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of a Broken or Risky Cryptographic Algorithm CVSS 3.1MEDIUM 6.5
Sources
- CVE-2020-16222 · CVE Program
- CVE-2020-16222 · NVD
- FIRST EPSS
- GHSA-82hx-cp56-ffj8 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences