Cross-site scripting in EcoStruxure Power Monitoring Expert
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- Required
- Attack complexity
- Low
- Impact type
- Cross-site scripting
- Confidentiality · integrity · availability
- Low · Low · None
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-79.
Summary
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | EcoStruxure Power Monitoring Expert (Versions 2020 and prior) | EcoStruxure Power Monitoring Expert (Versions 2020 and prior) | — | No fix listed | CNA |
- EcoStruxure Power Monitoring Expert (Versions 2020 and prior) Vendor— Affected EcoStruxure Power Monitoring Expert (Versions 2020 and prior) Fixed in — No fix listed CNA
CPE configurations NVD · 1
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:* | up to 2020 | Vulnerable | Schneider Electric |
- cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:* Versions up to 2020 Vulnerable ·Schneider Electric
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2022-22804
- 2026-10-03 Alias added: GHSA-m9fg-jg2j-wc72
More Schneider Electric Ecostruxure Power Monitoring Expert vulnerabilities
- TI-2023-04962 Deserialization of untrusted data in Schneider Electric EcoStruxure Power Monitoring… CVSS 3.1CRITICAL 9.8
- TI-2022-06977 Improper input validation in EcoStruxure Power Monitoring Expert CVSS 3.1HIGH 8.8
- TI-2020-06070 Improper access control in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA… CVSS 3.1HIGH 8.8
- TI-2023-12591 Insufficient session expiration in Schneider Electric EcoStruxure Power Monitoring Expert CVSS 3.1HIGH 8.8
- TI-2021-05707 A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code… CVSS 3.1HIGH 8.8
- TI-2021-05706 A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code… CVSS 3.1HIGH 8.8
Sources
- CVE-2022-22804 · CVE Program
- CVE-2022-22804 · NVD
- FIRST EPSS
- GHSA-m9fg-jg2j-wc72 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences