Read the docs

Schneider Electric

Records889All Threatist records
Exploited (KEV)1In CISA KEV
CVSS critical178CVSS 9.0–10.0
CVSS high452CVSS 7.0–8.9

Exploited now

Schneider Electric records in CISA KEV

Components

Products in the NVD configurations · select one to filter the records

Records

14 records in Ecostruxure Power Monitoring Expert · all components

Priority MEDIUM 41

A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user�s local machine when…

CVSS 3.1HIGH 8.8 Network No auth User interaction EPSS 0.01235 Published 2022-02-04 No fix listed CWE-20
Priority MEDIUM 41

A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to pe…

CVSS 3.1HIGH 8.8 Network Low privileges No interaction EPSS 0.01314 Published 2020-12-01 No fix listed CWE-284
Priority LOW 38

CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsaf…

CVSS 4.0HIGH 8.5 Local Low privileges No interaction EPSS 0.00218 Published 2026-03-10 No fix listed CWE-502
Priority LOW 36

A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execut…

CVSS 3.1HIGH 7.2 Network High privileges No interaction EPSS 0.02082 Published 2020-12-01 No fix listed CWE-284
Priority LOW 30

A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account.

CVSS 3.1MEDIUM 6.5 Network Low privileges No interaction EPSS 0.00771 Published 2022-02-04 No fix listed CWE-20
Priority LOW 29

A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert 1.3 (formerly Power Man…

CVSS 3.0MEDIUM 6.1 Network No auth User interaction EPSS 0.00755 Published 2018-12-17 No fix listed CWE-601
Priority LOW 27

A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s b…

CVSS 3.1MEDIUM 6.1 Network No auth User interaction EPSS 0.00406 Published 2023-11-15 No fix listed CWE-79
Priority LOW 25

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the…

CVSS 3.1MEDIUM 5.4 Network Low privileges User interaction EPSS 0.00451 Published 2022-02-04 No fix listed CWE-79
Priority LOW 25

A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that c…

CVSS 3.1MEDIUM 5.4 Network Low privileges User interaction EPSS 0.00625 Published 2020-12-01 No fix listed CWE-79