Deserialization of untrusted data in Schneider Electric EcoStruxure Power Monitoring…
Priority MEDIUM 51CWE-502Published · Updated
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-502.
Summary
A CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to execute arbitrary code on the targeted system by sending a specifically crafted packet to the application.
Why it matters now
Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00923 60th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- Yes
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Schneider Electric | EcoStruxure Power Monitoring Expert | All versions – prior to application of Hotfix-145271 | — | No fix listed | CNA |
| Schneider Electric | EcoStruxure Power Operation (EPO) with Advanced Reports | All versions – prior to application of Hotfix-145271 | — | No fix listed | CNA |
| Schneider Electric | EcoStruxure Power SCADA Operation with Advanced Reports | All versions – prior to application of Hotfix-145271 | — | No fix listed | CNA |
- EcoStruxure Power Monitoring Expert VendorSchneider Electric Affected All versions – prior to application of Hotfix-145271 Fixed in — No fix listed CNA
- EcoStruxure Power Operation (EPO) with Advanced Reports VendorSchneider Electric Affected All versions – prior to application of Hotfix-145271 Fixed in — No fix listed CNA
- EcoStruxure Power SCADA Operation with Advanced Reports VendorSchneider Electric Affected All versions – prior to application of Hotfix-145271 Fixed in — No fix listed CNA
CPE configurations NVD · 3
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:* | all versions | Vulnerable | Schneider Electric |
| cpe:2.3:a:schneider-electric:ecostruxure_power_operation_with_advanced_reports:*:*:*:*:*:*:*:* | all versions | Vulnerable | Schneider Electric |
| cpe:2.3:a:schneider-electric:ecostruxure_power_scada_operation_with_advanced_reports:*:*:*:*:*:*:*:* | all versions | Vulnerable | Schneider Electric |
- cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
- cpe:2.3:a:schneider-electric:ecostruxure_power_operation_with_advanced_reports:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
- cpe:2.3:a:schneider-electric:ecostruxure_power_scada_operation_with_advanced_reports:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2023-5391
- 2026-10-03 Alias added: GHSA-w228-frcg-5x99
References
More Schneider Electric Ecostruxure Power Monitoring Expert vulnerabilities
- TI-2022-06977 Improper input validation in EcoStruxure Power Monitoring Expert CVSS 3.1HIGH 8.8
- TI-2020-06070 Improper access control in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA… CVSS 3.1HIGH 8.8
- TI-2023-12591 Insufficient session expiration in Schneider Electric EcoStruxure Power Monitoring Expert CVSS 3.1HIGH 8.8
- TI-2021-05707 A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code… CVSS 3.1HIGH 8.8
- TI-2021-05706 A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code… CVSS 3.1HIGH 8.8
- TI-2025-10763 Deserialization of untrusted data in Schneider Electric EcoStruxure™ Power Monitoring… CVSS 4.0HIGH 8.5
Sources
- CVE-2023-5391 · CVE Program
- CVE-2023-5391 · NVD
- FIRST EPSS
- GHSA-w228-frcg-5x99 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences