Read the docs
TI-2025-10763 Aliases CVE-2025-11739GHSA-8hcj-8666-8jwh

Deserialization of untrusted data in Schneider Electric EcoStruxure™ Power Monitoring…

Priority LOW 38CWE-502Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-502.

Summary

CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00218 12th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Schneider ElectricEcoStruxure™ Power Monitoring Expert (PME)Version 2022; Version 2023; Version 2023 R2; Version 2024; Version 2024 R2—No fix listedCNA
Schneider ElectricEcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards ModuleVersion 2022; Version 2024—No fix listedCNA
  • EcoStruxure™ Power Monitoring Expert (PME) VendorSchneider Electric Affected Version 2022; Version 2023; Version 2023 R2; Version 2024; Version 2024 R2 Fixed in — No fix listed CNA
  • EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards Module VendorSchneider Electric Affected Version 2022; Version 2024 Fixed in — No fix listed CNA

CPE configurations NVD · 7

CPEVersionsRoleVendor
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2022:*:*:*:*:*:*:*2022VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2023:-:*:*:*:*:*:*2023VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2023:r2:*:*:*:*:*:*2023 r2VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2024:-:*:*:*:*:*:*2024VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2024:r2:*:*:*:*:*:*2024 r2VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:ecostruxure_power_operation:2022:*:*:*:*:*:*:*2022VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:ecostruxure_power_operation:2024:*:*:*:*:*:*:*2024VulnerableSchneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2022:*:*:*:*:*:*:* Versions 2022 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2023:-:*:*:*:*:*:* Versions 2023 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2023:r2:*:*:*:*:*:* Versions 2023 r2 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2024:-:*:*:*:*:*:* Versions 2024 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2024:r2:*:*:*:*:*:* Versions 2024 r2 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_power_operation:2022:*:*:*:*:*:*:* Versions 2022 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_power_operation:2024:*:*:*:*:*:*:* Versions 2024 Vulnerable ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-11739
  2. 2026-10-03 Alias added: GHSA-8hcj-8666-8jwh

References

  • TI-2023-04962 Deserialization of untrusted data in Schneider Electric EcoStruxure Power Monitoring… CVSS 3.1CRITICAL 9.8
  • TI-2022-06977 Improper input validation in EcoStruxure Power Monitoring Expert CVSS 3.1HIGH 8.8
  • TI-2020-06070 Improper access control in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA… CVSS 3.1HIGH 8.8
  • TI-2023-12591 Insufficient session expiration in Schneider Electric EcoStruxure Power Monitoring Expert CVSS 3.1HIGH 8.8
  • TI-2021-05707 A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code… CVSS 3.1HIGH 8.8
  • TI-2021-05706 A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code… CVSS 3.1HIGH 8.8
See all 13 →

Sources