Life2000 service tools for test and calibration do not support user authentication

Priority MEDIUM 50CWE-306Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-306.

Summary

The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the calibration tool, without having to authenticate to either tool. This could result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00695 53rd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
BaxterLife2000 Ventilation Systemup to 06.08.00.00—No fix listedCNA
  • Life2000 Ventilation System VendorBaxter Affected up to 06.08.00.00 Fixed in — No fix listed CNA

CPE names CISA-ADP · 1

CPEVersionsRoleVendor
cpe:2.3:o:baxter:life2000_ventilator_firmware:*:*:*:*:*:*:*:*——Baxter
  • cpe:2.3:o:baxter:life2000_ventilator_firmware:*:*:*:*:*:*:*:* Versions — — ·Baxter

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-48966
  2. 2026-10-03 Alias added: GHSA-285j-vfp9-5w9w

References

  • TI-2024-32651 Life2000 ventilator and Service PC lack sufficient audit logging capabilities CVSS 3.1CRITICAL 10.0
  • TI-2024-06298 Vulnerability in Baxter Connex Health Portal CVSS 3.1CRITICAL 10.0
  • TI-2014-04431 Improper authentication in Baxter SIGMA Spectrum Infusion System CVSS 3.0CRITICAL 9.8
  • TI-2020-09702 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for… CVSS 3.1CRITICAL 9.8
  • TI-2020-09675 Hard-coded credentials in Baxter ExactaMix EM 2400 & EM 1200 CVSS 3.1CRITICAL 9.8
  • TI-2014-04432 Cleartext storage of sensitive information in Baxter SIGMA Spectrum Infusion System CVSS 3.0CRITICAL 9.8
See all 36 →

Sources