Read the docs
TI-2025-07335 Aliases CVE-2025-8017GHSA-x7rp-rm5v-55v3

Tenda AC7 httpd setMacFilterCfg formSetMacFilterCfg stack-based overflow

Priority HIGH 73CWE-119Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.

Summary

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.13198 96th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA and NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TendaAC715.03.06.44—No fix listedCNA
  • AC7 VendorTenda Affected 15.03.06.44 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*15.03.06.44VulnerableTenda
cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*1.0Running onTenda
  • cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:* Versions 15.03.06.44 Vulnerable ·Tenda
  • cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:* Versions 1.0 Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-8017
  2. 2026-10-03 Alias added: GHSA-x7rp-rm5v-55v3

References

  • TI-2018-10434 An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7)… KEVCVSS 3.1CRITICAL 9.8
  • TI-2026-37683 In Tenda AC7 v15.03.06.44, the wanSpeed parameter of the route /goform/AdvSetMacMtuWan… CVSS 3.1CRITICAL 9.8
  • TI-2026-37682 Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the… CVSS 3.1CRITICAL 9.8
  • TI-2026-37681 Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the… CVSS 3.1CRITICAL 9.8
  • TI-2026-37680 Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the… CVSS 3.1CRITICAL 9.8
  • TI-2025-20996 A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote… CVSS 3.1CRITICAL 9.8
See all 71 →

Sources