Priority CRITICAL 100KEV
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10).
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.0851 · Published 2018-10-30 · No fix listed CWE-78
Priority HIGH 82
In Tenda AC7 v15.03.06.44, the wanSpeed parameter of the route /goform/AdvSetMacMtuWan has a stack buffer overflow vulnerability that can lead to remote arbitrary code execution.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00845 · Published 2026-06-19 · No fix listed CWE-121
Priority HIGH 82
Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the mac parameter.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00555 · Published 2026-06-19 · No fix listed CWE-121
Priority HIGH 82
Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the cloneType parameter.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00555 · Published 2026-06-19 · No fix listed CWE-121
Priority HIGH 82
Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the /goform/AdvSetMacMtuWan interface via the wanMTU parameter.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00555 · Published 2026-06-19 · No fix listed CWE-121
Priority HIGH 82
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01096 · Published 2025-03-24 · No fix listed CWE-121
Priority HIGH 82
Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00807 · Published 2024-04-17 · No fix listed CWE-125
Priority HIGH 82
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to conta…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00838 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a s…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.0085 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the dev…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00838 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to c…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00838 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter func…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00838 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00928 · Published 2023-07-14 · No fix listed CWE-787
Priority HIGH 82
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00928 · Published 2023-07-14 · No fix listed CWE-787
Priority HIGH 82
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00928 · Published 2023-07-14 · No fix listed CWE-787
Priority HIGH 73
A flaw has been found in Tenda AC7 15.03.06.44.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.00644 · Published 2026-03-27 · No fix listed CWE-119
Priority HIGH 73
A vulnerability was identified in Tenda AC7 15.03.06.44.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.00817 · Published 2025-10-09 · No fix listed CWE-119
Priority HIGH 73
A vulnerability was determined in Tenda AC7 15.03.06.44.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.00817 · Published 2025-10-09 · No fix listed CWE-119
Priority HIGH 73
A vulnerability was found in Tenda AC7 15.03.06.44.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.00821 · Published 2025-10-09 · No fix listed CWE-119
Priority HIGH 73
A vulnerability has been found in Tenda AC7 15.03.06.44.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.01057 · Published 2025-10-09 · No fix listed CWE-119
Priority HIGH 73
A flaw has been found in Tenda AC7 15.03.06.44.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.01053 · Published 2025-10-09 · No fix listed CWE-119
Priority HIGH 73
A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.00942 · Published 2025-08-15 · No fix listed CWE-119
Priority HIGH 73
A vulnerability was found in Tenda AC7 15.03.06.44.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.13198 · Published 2025-07-22 · No fix listed CWE-119
Priority HIGH 73
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.01108 · Published 2025-06-09 · No fix listed CWE-119
Priority HIGH 73
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.07572 · Published 2025-06-09 · No fix listed CWE-119
Load more