Read the docs
TI-2025-08002 Aliases CVE-2025-8748GHSA-q792-xxc2-jx5c

OS command injection in MiR robots and MiR fleet via crafted HTTP requests

Priority MEDIUM 43CWE-78Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-78.

Summary

MiR software versions prior to version 3.0.0 are affected by a command injection vulnerability. A malicious HTTP request crafted by an authenticated user could allow the execution of arbitrary commands on the underlying operating system.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.01338 71st percentileScored 2026-11-07
Fix Fixed MiR Robots (Mobile Industrial Robots): 3.0.0MiR Fleet (Mobile Industrial Robots): 3.0.0

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Mobile Industrial Robots A/SMiR Robotsbefore 3.0.03.0.0Patch availableCNA
Mobile Industrial Robots A/SMiR Fleetbefore 3.0.03.0.0Patch availableCNA

Remediation

  • Fix · CNA MiR Robots (Mobile Industrial Robots) Fixed in 3.0.0
  • Fix · CNA MiR Fleet (Mobile Industrial Robots) Fixed in 3.0.0

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Mobile Industrial Robots MiR Robots 3.0.0

    2 records Highest priority Priority MEDIUM 1 MEDIUM, 1 LOW

    Other records, highest priority first

    • TI-2025-08003 Path traversal vulnerability in MiR robot software via API requestsPriority LOW 29

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-8748
  2. 2026-10-03 Alias added: GHSA-q792-xxc2-jx5c

References

  • TI-2020-08279 RVD#2554: MiR ROS computational graph presents no authentication mechanisms CVSS 3.1CRITICAL 9.8
  • TI-2020-08278 Exposure of resource to wrong sphere in Mobile Industrial Robots A/S MiR100 CVSS 3.1CRITICAL 9.8
  • TI-2020-08283 RVD#2558: Default credentials on SICK PLC allows disabling safety features CVSS 3.1CRITICAL 9.8
  • TI-2020-08277 RVD#2557: Hardcoded Credentials on MiRX00 Control Dashboard CVSS 3.1CRITICAL 9.8
  • TI-2020-08276 RVD#2566: Hardcoded Credentials on MiRX00 wireless Access Point CVSS 3.1CRITICAL 9.8
  • TI-2020-08286 RVD#2569: Insecure operating system defaults in MiR robots CVSS 3.1CRITICAL 9.8
See all 16 →