Read the docs
TI-2025-30195 Aliases CVE-2025-47698GHSA-7cx6-7grp-mp5x

Cleartext transmission of sensitive information in Cognex In-Sight 2000 series

Priority LOW 38CWE-319Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
Passive
Attack complexity
Low
Attack requirements
None
Impact type
Information disclosure
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-319.

Summary

An adjacent attacker without authentication can exploit this vulnerability to retrieve a set of user-privileged credentials. These credentials are present during the firmware upgrade procedure.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00139 3rd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
CognexIn-Sight 2000 series5.x – 6.5.1—No fix listedCNA
CognexIn-Sight 7000 series5.x – 6.5.1—No fix listedCNA
CognexIn-Sight 8000 series5.x – 6.5.1—No fix listedCNA
CognexIn-Sight 9000 series5.x – 6.5.1—No fix listedCNA
CognexIn-Sight Explorer5.x – 6.5.1—No fix listedCNA
  • In-Sight 2000 series VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA
  • In-Sight 7000 series VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA
  • In-Sight 8000 series VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA
  • In-Sight 9000 series VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA
  • In-Sight Explorer VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-47698
  2. 2026-10-03 Alias added: GHSA-7cx6-7grp-mp5x

References

  • TI-2022-01249 Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function CVSS 3.1CRITICAL 9.8
  • TI-2022-01398 Cognex 3D-A1000 Dimensioning System Client-Side Enforcement of Server-Side Security CVSS 3.1CRITICAL 9.1
  • TI-2021-12544 Cognex In-Sight OPC Server - Deserialization of Untrusted Data CVSS 3.1CRITICAL 9.8
  • TI-2025-34564 Cognex In-Sight Explorer and In-Sight Camera Firmware Authentication Bypass by Capture-replay CVSS 4.0HIGH 8.6
  • TI-2025-34516 Cognex In-Sight Explorer and In-Sight Camera Firmware Use of Hard-coded Password CVSS 4.0HIGH 8.6
  • TI-2025-33825 Cognex In-Sight Explorer and In-Sight Camera Firmware Client-Side Enforcement of Server-Side Security CVSS 4.0HIGH 8.6
See all 12 →

Sources