Read the docs
TI-2026-03903 Aliases CVE-2026-4493GHSA-wvj3-4632-88jj

Tenda A18 Pro MAC Filtering Configuration Endpoint setMacFilterCfg sub_423B50 stack-based overflow

Priority HIGH 73CWE-119Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.

Summary

A vulnerability was determined in Tenda A18 Pro 02.03.02.28. The impacted element is the function sub_423B50 of the file /goform/setMacFilterCfg of the component MAC Filtering Configuration Endpoint. Executing a manipulation of the argument deviceList can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.0066 51st percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TendaA18 Pro02.03.02.28—No fix listedCNA
  • A18 Pro VendorTenda Affected 02.03.02.28 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-4493
  2. 2026-10-03 Alias added: GHSA-wvj3-4632-88jj

References

  • TI-2021-11772 An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. KEVCVSS 3.1CRITICAL 9.8
  • TI-2020-08863 The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote… KEVCVSS 3.1CRITICAL 9.8
  • TI-2018-10434 An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7)… KEVCVSS 3.1CRITICAL 9.8
  • TI-2026-78650 Stack-based buffer overflow in Tenda AC19 web management service CVSS 4.0CRITICAL 10.0
  • TI-2026-66119 Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow CVSS 4.0CRITICAL 10.0
  • TI-2026-57025 Tenda AC18 Telnet telnet missing authentication CVSS 4.0CRITICAL 10.0
See all 1963 →

Sources