Tenda AC7 Exposes Admin Credentials in Configuration Responses
Key facts
- Attack vector
- Local
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Information disclosure
- Confidentiality · integrity · availability
- High · None · None
- Fix status
- No fix listed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-201.
Summary
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose sensitive information in web management responses. Administrative credentials, including the router and/or admin panel password, are included in plaintext within configuration response bodies. In addition, responses lack appropriate Cache-Control directives, which may permit web browsers to cache pages containing these credentials and enable subsequent disclosure to an attacker with access to the client system or browser profile.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Tenda | Tenda AC7 | up to 03.03.03.01_cn | — | No fix listed | CNA |
- Tenda AC7 VendorTenda Affected up to 03.03.03.01_cn Fixed in — No fix listed CNA
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2026-24427
- 2026-10-03 Alias added: GHSA-6rpr-9cmg-mvvj
References
More Tenda Ac7 Firmware vulnerabilities
- TI-2018-10434 An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7)… KEVCVSS 3.1CRITICAL 9.8
- TI-2026-37683 In Tenda AC7 v15.03.06.44, the wanSpeed parameter of the route /goform/AdvSetMacMtuWan… CVSS 3.1CRITICAL 9.8
- TI-2026-37682 Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the… CVSS 3.1CRITICAL 9.8
- TI-2026-37681 Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the… CVSS 3.1CRITICAL 9.8
- TI-2026-37680 Tenda AC7 v15.03.06.44 contains a stack buffer overflow vulnerability in the… CVSS 3.1CRITICAL 9.8
- TI-2025-20996 A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote… CVSS 3.1CRITICAL 9.8