Read the docs
TI-2026-54301 Aliases CVE-2026-78063GHSA-x5qw-fmv8-fhx9

Tenda CH22 editFileName formeditFileName command injection

Priority MEDIUM 57CWE-74Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
Low · Low · Low
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-77.

Summary

A security flaw has been discovered in Tenda CH22 1.0.0.1. The impacted element is the function formeditFileName of the file /goform/editFileName. The manipulation of the argument editNameMit results in command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.02747 86th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TendaCH221.0.0.1—No fix listedCNA
  • CH22 VendorTenda Affected 1.0.0.1 Fixed in — No fix listed CNA

CPE names CNA · 1

CPEVersionsRoleVendor
cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*——Tenda
  • cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:* Versions — — ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-78063
  2. 2026-10-03 Alias added: GHSA-x5qw-fmv8-fhx9

References

  • TI-2021-11772 An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. KEVCVSS 3.1CRITICAL 9.8
  • TI-2020-08863 The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote… KEVCVSS 3.1CRITICAL 9.8
  • TI-2018-10434 An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7)… KEVCVSS 3.1CRITICAL 9.8
  • TI-2026-78650 Stack-based buffer overflow in Tenda AC19 web management service CVSS 4.0CRITICAL 10.0
  • TI-2026-66119 Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow CVSS 4.0CRITICAL 10.0
  • TI-2026-57025 Tenda AC18 Telnet telnet missing authentication CVSS 4.0CRITICAL 10.0
See all 1963 →

Sources