Read the docs
TI-2026-58461 Aliases CVE-2026-85109GHSA-w4wj-hq79-xrch

Tenda HG10 Boa Web Server formLogin buffer overflow

Priority HIGH 81CWE-119Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.

Summary

A vulnerability was determined in Tenda HG10 300001138. This issue affects the function formLogin of the file /boaform/formLogin of the component Boa Web Server. Executing a manipulation of the argument Username can lead to buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.01096 65th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
Yes
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
TendaHG10300001138—No fix listedCNA
  • HG10 VendorTenda Affected 300001138 Fixed in — No fix listed CNA

CPE names CNA · 1

CPEVersionsRoleVendor
cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*——Tenda
  • cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:* Versions — — ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-85109
  2. 2026-10-03 Alias added: GHSA-w4wj-hq79-xrch

References

  • TI-2021-11772 An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. KEVCVSS 3.1CRITICAL 9.8
  • TI-2020-08863 The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote… KEVCVSS 3.1CRITICAL 9.8
  • TI-2018-10434 An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7)… KEVCVSS 3.1CRITICAL 9.8
  • TI-2026-78650 Stack-based buffer overflow in Tenda AC19 web management service CVSS 4.0CRITICAL 10.0
  • TI-2026-66119 Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow CVSS 4.0CRITICAL 10.0
  • TI-2026-57025 Tenda AC18 Telnet telnet missing authentication CVSS 4.0CRITICAL 10.0
See all 1962 →

Sources