Read the docs

Hard-coded credentials in CompuGroup Medical Phronesis and Venere

Priority MEDIUM 43CWE-798Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-798.

Summary

CompuGroup Medical Phronesis and Venere through 5.1.15.1.1 ship a shared AIS login component that selects a test data access object and compares passwords in plaintext for the H and V application codes. Because the fixed administrator accounts are accepted, a remote attacker without credentials can log in as an administrator and read, change or disrupt data (CWE-798).

Written with Claude Haiku 5.5 from the sources below · 2026-11-09

Description from the CNA

The shared AIS login routing selects a production-shipped test DAO and plaintext comparison for the H and V application codes, accepting fixed administrator accounts.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00249 16th percentileScored 2026-11-16
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
CompuGroup MedicalPhronesisup to 5.1.15.1.1—No fix listedCNA
CompuGroup MedicalVenereup to 5.1.15.1.1—No fix listedCNA

Remediation

The sources list no fixed version for Phronesis. The sources list no fixed version for Venere.

Written with Claude Haiku 5.5 from the sources below · 2026-11-09

Timeline

  1. 2026-11-09 Threatist record created from CVE-2026-118458
  2. 2026-11-09 Alias added: GHSA-q79g-wr42-5523
  3. 2026-11-11 Priority changed: MEDIUM → LOW
  4. 2026-11-12 CISA SSVC decision points changed
  5. 2026-11-12 Priority changed: LOW → MEDIUM

References

  • TI-2026-87100 Unauthenticated doctor operations in CompuGroup Medical AIS client CVSS 4.0HIGH 8.0
  • TI-2026-87094 SQL injection in CompuGroup Medical XDent and XMedical synchronization CVSS 4.0HIGH 8.1
  • TI-2026-87099 Hard-coded keys in CompuGroup AIS allow practitioner impersonation CVSS 4.0HIGH 8.0
  • TI-2025-31109 An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows… CVSS 3.1HIGH 8.6
  • TI-2026-87101 Unverified update code execution in CompuGroup Medical products CVSS 4.0CRITICAL 9.2
  • TI-2026-87108 Insecure software update mechanism in CompuGroup Medical Wingesfar CVSS 4.0HIGH 7.2
See all 16 →