Hard-coded keys in CompuGroup AIS allow practitioner impersonation
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Security bypass
- Confidentiality · integrity · availability
- High · High · None
- Fix status
- No fix listed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-321.
Summary
CompuGroup Medical Infantia, Profim, Venere and Phronesis are affected from 0 through 6.09.1 and from 0 through 5.1.1. Embedded private keys protected by a shared password let an attacker sign practitioner assertions for arbitrary practitioner identifiers (CWE-321). A remote, unauthenticated attacker can request unauthorized practitioner tokens with high confidentiality and integrity impact.
Written with Claude Haiku 5.5 from the sources below · 2026-11-09
Description from the CNA
Embedded private keys protected by a shared password can be used to sign practitioner assertions for arbitrary practitioner identifiers, enabling unauthorized practitioner token requests.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- Yes
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| CompuGroup Medical | Infantia | up to 6.09.1 | — | No fix listed | CNA |
| CompuGroup Medical | Profim | up to 6.09.1 | — | No fix listed | CNA |
| CompuGroup Medical | Venere | up to 6.09.1 | — | No fix listed | CNA |
| CompuGroup Medical | Phronesis | up to 6.09.1 | — | No fix listed | CNA |
| CompuGroup Medical | Infantia | up to 5.1.1 | — | No fix listed | CNA |
| CompuGroup Medical | Profim | up to 5.1.1 | — | No fix listed | CNA |
| CompuGroup Medical | Venere | up to 5.1.1 | — | No fix listed | CNA |
| CompuGroup Medical | Phronesis | up to 5.1.1 | — | No fix listed | CNA |
- Infantia VendorCompuGroup Medical Affected up to 6.09.1 Fixed in — No fix listed CNA
- Profim VendorCompuGroup Medical Affected up to 6.09.1 Fixed in — No fix listed CNA
- Venere VendorCompuGroup Medical Affected up to 6.09.1 Fixed in — No fix listed CNA
- Phronesis VendorCompuGroup Medical Affected up to 6.09.1 Fixed in — No fix listed CNA
- Infantia VendorCompuGroup Medical Affected up to 5.1.1 Fixed in — No fix listed CNA
- Profim VendorCompuGroup Medical Affected up to 5.1.1 Fixed in — No fix listed CNA
- Venere VendorCompuGroup Medical Affected up to 5.1.1 Fixed in — No fix listed CNA
- Phronesis VendorCompuGroup Medical Affected up to 5.1.1 Fixed in — No fix listed CNA
Remediation
The sources list no fixed version for Infantia, Profim, Venere or Phronesis.
Written with Claude Haiku 5.5 from the sources below · 2026-11-09
Timeline
- 2026-11-09 Threatist record created from CVE-2026-118460
- 2026-11-09 Alias added: GHSA-38qv-wpc5-5q7v
- 2026-11-11 Priority changed: MEDIUM → LOW
- 2026-11-12 CISA SSVC decision points changed
- 2026-11-12 Priority changed: LOW → MEDIUM
References
More CompuGroup Medical vulnerabilities
- TI-2026-87100 Unauthenticated doctor operations in CompuGroup Medical AIS client CVSS 4.0HIGH 8.0
- TI-2026-87097 Hard-coded credentials in CompuGroup Medical Phronesis and Venere CVSS 4.0HIGH 8.1
- TI-2026-87094 SQL injection in CompuGroup Medical XDent and XMedical synchronization CVSS 4.0HIGH 8.1
- TI-2025-31109 An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows… CVSS 3.1HIGH 8.6
- TI-2026-87101 Unverified update code execution in CompuGroup Medical products CVSS 4.0CRITICAL 9.2
- TI-2026-87108 Insecure software update mechanism in CompuGroup Medical Wingesfar CVSS 4.0HIGH 7.2
Sources
- CVE-2026-118460 · CVE Program
- CVE-2026-118460 · NVD
- FIRST EPSS
- GHSA-38qv-wpc5-5q7v · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences