Read the docs

Insecure software update mechanism in CompuGroup Medical Wingesfar

Priority LOW 33CWE-494Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
Present
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-494.

Summary

CompuGroup Medical Wingesfar from 0 before 10.2.1 implements software update functionality without adequate authenticity and integrity validation. Because it accepts update packages without sufficient cryptographic verification (CWE-494), an unauthenticated remote attacker can have malicious update packages accepted. The CVSS 4.0 base score is 7.2 (HIGH).

Written with Claude Haiku 5.5 from the sources below · 2026-11-09

Description from the CNA

The application implements software update functionality without adequate authenticity and integrity validation, allowing update packages to be accepted without sufficient cryptographic verification.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00157 4th percentileScored 2026-11-16
Fix Fixed Wingesfar (CompuGroup Medical): 10.2.1

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
CompuGroup MedicalWingesfarbefore 10.2.110.2.1Patch availableCNA
  • Wingesfar VendorCompuGroup Medical Affected before 10.2.1 Fixed in 10.2.1 Patch available CNA

Remediation

Update CompuGroup Medical Wingesfar to version 10.2.1, which is the fixed version listed for this product.

Written with Claude Haiku 5.5 from the sources below · 2026-11-09

  • Fix · CNA Wingesfar (CompuGroup Medical) Fixed in 10.2.1

Timeline

  1. 2026-11-09 Threatist record created from CVE-2026-118791
  2. 2026-11-09 Alias added: GHSA-43cf-6fxq-3qw6
  3. 2026-11-11 Priority changed: MEDIUM → LOW
  4. 2026-11-12 CISA SSVC decision points changed

References

  • TI-2026-87100 Unauthenticated doctor operations in CompuGroup Medical AIS client CVSS 4.0HIGH 8.0
  • TI-2026-87097 Hard-coded credentials in CompuGroup Medical Phronesis and Venere CVSS 4.0HIGH 8.1
  • TI-2026-87094 SQL injection in CompuGroup Medical XDent and XMedical synchronization CVSS 4.0HIGH 8.1
  • TI-2026-87099 Hard-coded keys in CompuGroup AIS allow practitioner impersonation CVSS 4.0HIGH 8.0
  • TI-2025-31109 An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows… CVSS 3.1HIGH 8.6
  • TI-2026-87101 Unverified update code execution in CompuGroup Medical products CVSS 4.0CRITICAL 9.2
See all 16 →

Sources