AIS products use vendor-wide hard-coded database credentials
Key facts
- Attack vector
- Local
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Security bypass
- Confidentiality · integrity · availability
- High · High · None
- Fix status
- No fix listed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-798.
Summary
CompuGroup Medical Infantia, Profim, Venere and Phronesis, versions through 5.1.1, ship shared components with hard-coded database credentials (CWE-798). The Access, workgroup, CCBasic and DBISAM credentials are identical across installations. A local user with low privileges can use these credentials to access the database, with high confidentiality and integrity impact.
Written with Claude Haiku 5.5 from the sources below · 2026-11-09
Description from the CNA
Shared components expose hard-coded Access, workgroup, CCBasic, DBISAM, and related database credentials that are identical across installations.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| CompuGroup Medical | Infantia | up to 5.1.1 | — | No fix listed | CNA |
| CompuGroup Medical | Profim | up to 5.1.1 | — | No fix listed | CNA |
| CompuGroup Medical | Venere | up to 5.1.1 | — | No fix listed | CNA |
| CompuGroup Medical | Phronesis | up to 5.1.1 | — | No fix listed | CNA |
- Infantia VendorCompuGroup Medical Affected up to 5.1.1 Fixed in — No fix listed CNA
- Profim VendorCompuGroup Medical Affected up to 5.1.1 Fixed in — No fix listed CNA
- Venere VendorCompuGroup Medical Affected up to 5.1.1 Fixed in — No fix listed CNA
- Phronesis VendorCompuGroup Medical Affected up to 5.1.1 Fixed in — No fix listed CNA
Remediation
No fixed version is listed for Infantia, Profim, Venere or Phronesis.
Written with Claude Haiku 5.5 from the sources below · 2026-11-09
Timeline
- 2026-11-09 Threatist record created from CVE-2026-118465
- 2026-11-09 Alias added: GHSA-4vj2-9mfw-mppf
- 2026-11-11 Priority changed: MEDIUM → LOW
- 2026-11-12 CISA SSVC decision points changed
References
More CompuGroup Medical vulnerabilities
- TI-2026-87100 Unauthenticated doctor operations in CompuGroup Medical AIS client CVSS 4.0HIGH 8.0
- TI-2026-87097 Hard-coded credentials in CompuGroup Medical Phronesis and Venere CVSS 4.0HIGH 8.1
- TI-2026-87094 SQL injection in CompuGroup Medical XDent and XMedical synchronization CVSS 4.0HIGH 8.1
- TI-2026-87099 Hard-coded keys in CompuGroup AIS allow practitioner impersonation CVSS 4.0HIGH 8.0
- TI-2025-31109 An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows… CVSS 3.1HIGH 8.6
- TI-2026-87101 Unverified update code execution in CompuGroup Medical products CVSS 4.0CRITICAL 9.2
Sources
- CVE-2026-118465 · CVE Program
- CVE-2026-118465 · NVD
- FIRST EPSS
- GHSA-4vj2-9mfw-mppf · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences