Sensitive patient data exposed in CompuGroup Medical AIS logs
Key facts
- Attack vector
- Local
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Information disclosure
- Confidentiality · integrity · availability
- High · None · None
- Fix status
- No fix listed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-532.
Summary
CompuGroup Medical Infantia, Profim, Venere and Phronesis, in versions from 0 through 1.3.1 and from 0 through 5.1.1, have a flaw in shared telemetry and logging components. These components store or transmit patient and doctor identifiers and clinical information without adequate pseudonymization, which is CWE-532. A local user with low privileges can read this sensitive data.
Written with Claude Haiku 5.5 from the sources below · 2026-11-09
Description from the CNA
Shared telemetry and logging components store or transmit patient and doctor identifiers, clinical information, and low-entropy identifiers without adequate pseudonymization or protection.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| CompuGroup Medical | Infantia | up to 1.3.1 | — | No fix listed | CNA |
| CompuGroup Medical | Profim | up to 1.3.1 | — | No fix listed | CNA |
| CompuGroup Medical | Venere | up to 1.3.1 | — | No fix listed | CNA |
| CompuGroup Medical | Phronesis | up to 1.3.1 | — | No fix listed | CNA |
| CompuGroup Medical | Infantia | up to 5.1.1 | — | No fix listed | CNA |
| CompuGroup Medical | Profim | up to 5.1.1 | — | No fix listed | CNA |
| CompuGroup Medical | Venere | up to 5.1.1 | — | No fix listed | CNA |
| CompuGroup Medical | Phronesis | up to 5.1.1 | — | No fix listed | CNA |
- Infantia VendorCompuGroup Medical Affected up to 1.3.1 Fixed in — No fix listed CNA
- Profim VendorCompuGroup Medical Affected up to 1.3.1 Fixed in — No fix listed CNA
- Venere VendorCompuGroup Medical Affected up to 1.3.1 Fixed in — No fix listed CNA
- Phronesis VendorCompuGroup Medical Affected up to 1.3.1 Fixed in — No fix listed CNA
- Infantia VendorCompuGroup Medical Affected up to 5.1.1 Fixed in — No fix listed CNA
- Profim VendorCompuGroup Medical Affected up to 5.1.1 Fixed in — No fix listed CNA
- Venere VendorCompuGroup Medical Affected up to 5.1.1 Fixed in — No fix listed CNA
- Phronesis VendorCompuGroup Medical Affected up to 5.1.1 Fixed in — No fix listed CNA
Remediation
The sources list no fixed version for Infantia. The sources list no fixed version for Profim. The sources list no fixed version for Venere. The sources list no fixed version for Phronesis.
Written with Claude Haiku 5.5 from the sources below · 2026-11-09
Timeline
- 2026-11-09 Threatist record created from CVE-2026-118467
- 2026-11-09 Alias added: GHSA-3jw5-w6q7-rw7g
- 2026-11-12 CISA SSVC decision points changed
References
More CompuGroup Medical vulnerabilities
- TI-2026-87100 Unauthenticated doctor operations in CompuGroup Medical AIS client CVSS 4.0HIGH 8.0
- TI-2026-87097 Hard-coded credentials in CompuGroup Medical Phronesis and Venere CVSS 4.0HIGH 8.1
- TI-2026-87094 SQL injection in CompuGroup Medical XDent and XMedical synchronization CVSS 4.0HIGH 8.1
- TI-2026-87099 Hard-coded keys in CompuGroup AIS allow practitioner impersonation CVSS 4.0HIGH 8.0
- TI-2025-31109 An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows… CVSS 3.1HIGH 8.6
- TI-2026-87101 Unverified update code execution in CompuGroup Medical products CVSS 4.0CRITICAL 9.2
Sources
- CVE-2026-118467 · CVE Program
- CVE-2026-118467 · NVD
- FIRST EPSS
- GHSA-3jw5-w6q7-rw7g · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences