XML external entity injection in AIS XML parsers
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- High
- Attack requirements
- Present
- Impact type
- —
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA.
Summary
CompuGroup Medical Infantia and Profim through 6.01.1, Phronesis through 4.51.0, and Venere through 8.33.2 have XML parsers that resolve external entities. CWE-611 means the parsers do not restrict external entity references when processing attacker-influenced update manifests or network responses. A remote attacker who can influence these inputs needs no privileges or user interaction, though attack complexity is high, and successful exploitation can affect confidentiality, integrity and availability.
Written with Claude Haiku 5.5 from the sources below · 2026-11-09
Description from the CNA
XML parsers process attacker-influenced update manifests or network responses with external entity resolution enabled, potentially allowing XML External Entity (XXE) attacks.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| CompuGroup Medical | Infantia | up to 6.01.1 | — | No fix listed | CNA |
| CompuGroup Medical | Profim | up to 6.01.1 | — | No fix listed | CNA |
| CompuGroup Medical | Phronesis | up to 4.51.0 | — | No fix listed | CNA |
| CompuGroup Medical | Venere | up to 8.33.2 | — | No fix listed | CNA |
- Infantia VendorCompuGroup Medical Affected up to 6.01.1 Fixed in — No fix listed CNA
- Profim VendorCompuGroup Medical Affected up to 6.01.1 Fixed in — No fix listed CNA
- Phronesis VendorCompuGroup Medical Affected up to 4.51.0 Fixed in — No fix listed CNA
- Venere VendorCompuGroup Medical Affected up to 8.33.2 Fixed in — No fix listed CNA
Remediation
The sources list no fixed version for Infantia. The sources list no fixed version for Profim. The sources list no fixed version for Phronesis. The sources list no fixed version for Venere.
Written with Claude Haiku 5.5 from the sources below · 2026-11-09
Timeline
- 2026-11-09 Threatist record created from CVE-2026-118468
- 2026-11-09 Alias added: GHSA-hxw6-573p-p5f4
- 2026-11-11 Priority changed: MEDIUM → LOW
- 2026-11-12 CISA SSVC decision points changed
References
More CompuGroup Medical vulnerabilities
- TI-2026-87100 Unauthenticated doctor operations in CompuGroup Medical AIS client CVSS 4.0HIGH 8.0
- TI-2026-87097 Hard-coded credentials in CompuGroup Medical Phronesis and Venere CVSS 4.0HIGH 8.1
- TI-2026-87094 SQL injection in CompuGroup Medical XDent and XMedical synchronization CVSS 4.0HIGH 8.1
- TI-2026-87099 Hard-coded keys in CompuGroup AIS allow practitioner impersonation CVSS 4.0HIGH 8.0
- TI-2025-31109 An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows… CVSS 3.1HIGH 8.6
- TI-2026-87101 Unverified update code execution in CompuGroup Medical products CVSS 4.0CRITICAL 9.2
Sources
- CVE-2026-118468 · CVE Program
- CVE-2026-118468 · NVD
- FIRST EPSS
- GHSA-hxw6-573p-p5f4 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences