Read the docs

AIS stores authorization data in locally modifiable databases

Priority LOW 27CWE-602Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA.

Summary

CompuGroup Medical Infantia and Profim through 6.09.1, and Venere through 8.33.2, are affected. Administrative roles and module permissions are stored in mutable local database fields, so the application relies on client-side data for security decisions (CWE-602). A local attacker with low privileges and write access to the database can escalate privileges.

Written with Claude Haiku 5.5 from the sources below · 2026-11-09

Description from the CNA

Administrative roles and module permissions are stored in mutable local database fields, allowing privilege escalation for attackers with database write access.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00138 3rd percentileScored 2026-11-16
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
CompuGroup MedicalInfantiaup to 6.09.1—No fix listedCNA
CompuGroup MedicalProfimup to 6.09.1—No fix listedCNA
CompuGroup MedicalVenereup to 8.33.2—No fix listedCNA

Remediation

The sources list no fixed version for Infantia. The sources list no fixed version for Profim. The sources list no fixed version for Venere.

Written with Claude Haiku 5.5 from the sources below · 2026-11-09

Timeline

  1. 2026-11-09 Threatist record created from CVE-2026-118795
  2. 2026-11-09 CISA SSVC decision points changed
  3. 2026-11-09 Priority changed: MEDIUM → LOW
  4. 2026-11-09 Alias added: GHSA-9vhh-5f3x-qx5v

References

  • TI-2026-87100 Unauthenticated doctor operations in CompuGroup Medical AIS client CVSS 4.0HIGH 8.0
  • TI-2026-87097 Hard-coded credentials in CompuGroup Medical Phronesis and Venere CVSS 4.0HIGH 8.1
  • TI-2026-87094 SQL injection in CompuGroup Medical XDent and XMedical synchronization CVSS 4.0HIGH 8.1
  • TI-2026-87099 Hard-coded keys in CompuGroup AIS allow practitioner impersonation CVSS 4.0HIGH 8.0
  • TI-2025-31109 An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows… CVSS 3.1HIGH 8.6
  • TI-2026-87101 Unverified update code execution in CompuGroup Medical products CVSS 4.0CRITICAL 9.2
See all 16 →