Insufficient data authenticity checks in Tenda AC18 firmware upgrade
Key facts
- Attack vector
- Network
- Privileges required
- High
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Security bypass
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-345.
Summary
Tenda AC18 versions 15.03.05.05_multi and 15.03.05.19 Build 6318 are affected. The firmware upgrade handler at /cgi-bin/upgrade does not sufficiently verify the authenticity of data supplied in the upgradeFile argument (CWE-345). A remote attacker with high privileges can exploit this flaw, and a public exploit is available.
Written with Claude Haiku 5.5 from the sources below · 2026-11-16
Description from the CNA
A vulnerability was identified in Tenda AC18 15.03.05.05_multi/15.03.05.19 Build 6318. Affected by this vulnerability is an unknown functionality of the file /cgi-bin/upgrade of the component Firmware Upgrade Handler. Such manipulation of the argument upgradeFile leads to insufficient verification of data authenticity. The attack may be launched remotely. The exploit is publicly available and might be used.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- Poc
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
Remediation
The sources list no fixed version for Tenda AC18.
Written with Claude Haiku 5.5 from the sources below · 2026-11-16
Timeline
- 2026-11-14 Threatist record created from CVE-2026-129258
- 2026-11-14 Alias added: GHSA-wxr2-fxvm-rgwm
- 2026-11-16 CISA SSVC decision points changed
References
More Tenda vulnerabilities
- TI-2021-11772 Stack buffer overflow in Tenda AC11 devices allows code execution KEVCVSS 3.1CRITICAL 9.8
- TI-2020-08863 OS command injection in Tenda AC15 AC1900 via deviceName parameter KEVCVSS 3.1CRITICAL 9.8
- TI-2018-10434 Command injection in Tenda AC7, AC9 and AC10 devices KEVCVSS 3.1CRITICAL 9.8
- TI-2026-86593 Heap-based buffer overflow in Tenda AC19 saveParentControlInfo CVSS 4.0CRITICAL 10.0
- TI-2026-78650 Stack-based buffer overflow in Tenda AC19 web management service CVSS 4.0CRITICAL 10.0
- TI-2026-66119 Tenda HG7/HG9/HG10 Boa Web Server formLoopBack boaGetVar stack-based overflow CVSS 4.0CRITICAL 10.0
Sources
- CVE-2026-129258 · CVE Program
- CVE-2026-129258 · NVD
- FIRST EPSS
- GHSA-wxr2-fxvm-rgwm · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences