Read the docs

Vulnerabilities published on

124 records. Those in CISA KEV come first, then the highest Threatist priority.

Records

RecordTitleCVSSPriority
TI-2016-05326
CVE-2016-6210
sshd in OpenSSH before 7.3, when SHA256 or SHA512 are used for user password hashing…CVSS MEDIUM 5.9Priority HIGH 69
TI-2016-07634
CVE-2016-9361
Missing brute-force protection in Moxa NPortCVSS CRITICAL 9.8Priority HIGH 68
TI-2016-07642
CVE-2016-9369
Missing authentication in Moxa NPortCVSS CRITICAL 9.8Priority MEDIUM 60
TI-2016-07619
CVE-2016-9343
Out-of-bounds write in Rockwell Automation Logix5000 Programmable Automation Controller…CVSS CRITICAL 10.0Priority MEDIUM 56
TI-2017-03280
CVE-2017-5162
Missing authentication in BINOM3 Electric Power Quality MeterCVSS CRITICAL 9.8Priority MEDIUM 56
TI-2016-07639
CVE-2016-9366
Missing brute-force protection in Moxa NPortCVSS CRITICAL 9.8Priority MEDIUM 55
TI-2016-06861
CVE-2016-8352
Memory corruption in Schneider Electric ConneXium TCSEFEC2*CVSS CRITICAL 10.0Priority MEDIUM 50
TI-2017-03272
CVE-2017-5154
SQL injection in Advantech WebAccess 8.1CVSS CRITICAL 9.8Priority MEDIUM 49
TI-2016-06859
CVE-2016-8348
XML external entity injection in Emerson Liebert SiteScan 6.5, and priorCVSS CRITICAL 9.8Priority MEDIUM 48
TI-2016-07273
CVE-2016-8859
Multiple integer overflows in the TRE library and musl libc allow attackers to cause…CVSS CRITICAL 9.8Priority MEDIUM 48
TI-2015-07217
CVE-2015-8768
click/install.py in click does not require files in package filesystem tarballs to start…CVSS CRITICAL 9.8Priority MEDIUM 47
TI-2015-07220
CVE-2015-8771
The generate_smb_nt_hash function in include/functions.inc in GOsa allows remote…CVSS CRITICAL 9.8Priority MEDIUM 47
TI-2016-05044
CVE-2016-5815
Improper access control in Schneider Electric IONXXXX Series Power Meter VulnerabilitiesCVSS CRITICAL 9.8Priority MEDIUM 47
TI-2016-06872
CVE-2016-8363
Access control flaw in Moxa OnCellCVSS CRITICAL 10.0Priority MEDIUM 47
TI-2016-06873
CVE-2016-8364
Memory corruption in IBHsoftec S7-SoftPLC CPX43 prior to 4.12bCVSS CRITICAL 9.8Priority MEDIUM 47
TI-2017-03264
CVE-2017-5144
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and…CVSS CRITICAL 9.8Priority MEDIUM 47
TI-2017-03277
CVE-2017-5159
An issue was discovered on Phoenix Contact mGuard devices that have been updated to…CVSS CRITICAL 9.8Priority MEDIUM 47
TI-2016-02330
CVE-2016-2788
MCollective 2.7.0 and 2.8.x before 2.8.9, as used in Puppet Enterprise, allows remote…CVSS CRITICAL 9.8Priority MEDIUM 46
TI-2016-04411
CVE-2016-5100
Froxlor before 0.9.35 uses the PHP rand function for random number generation, which…CVSS CRITICAL 9.8Priority MEDIUM 46
TI-2016-05047
CVE-2016-5818
Hard-coded credentials in Schneider Electric PowerLogic 2.651 and olderCVSS CRITICAL 9.8Priority MEDIUM 46
TI-2016-06430
CVE-2016-7565
install/index.php in Exponent CMS 2.3.9 allows remote attackers to execute arbitrary…CVSS CRITICAL 9.8Priority MEDIUM 46
TI-2016-06858
CVE-2016-8347
Improper authentication in Kabona AB WDC prior to Version 3.4.0CVSS CRITICAL 9.8Priority MEDIUM 46
TI-2016-06885
CVE-2016-8377
Memory corruption in Fatek Automation PLC WinProladder 3.11 Build 14701CVSS HIGH 8.0Priority MEDIUM 46
TI-2016-07039
CVE-2016-8567
Hard-coded credentials in Siemens SICAM PAS before 8.00CVSS CRITICAL 9.8Priority MEDIUM 46
TI-2016-07613
CVE-2016-9333
SQL injection in Moxa SoftCMS prior to Version 1.6CVSS CRITICAL 9.8Priority MEDIUM 46
TI-2017-03259
CVE-2017-5139
Insufficiently protected credentials in Honeywell XL Web II ControllerCVSS CRITICAL 9.8Priority MEDIUM 46
TI-2017-03260
CVE-2017-5140
Insufficiently protected credentials in Honeywell XL Web II ControllerCVSS CRITICAL 9.8Priority MEDIUM 46
TI-2017-03270
CVE-2017-5152
Improper authentication in Advantech WebAccess 8.1CVSS CRITICAL 9.1Priority MEDIUM 46
TI-2016-03069
CVE-2016-3616
The cjpeg utility in libjpeg allows remote attackers to cause a denial of service (NULL…CVSS HIGH 8.8Priority MEDIUM 45
TI-2016-06854
CVE-2016-8341
SQL injection in Ecava IntegraXor 5.0.413.0CVSS CRITICAL 9.8Priority MEDIUM 45
TI-2016-06864
CVE-2016-8355
Missing authentication in Smiths-Medical CADD-Solis Medication Safety Software through 3.1CVSS CRITICAL 9.9Priority MEDIUM 45
TI-2016-06886
CVE-2016-8378
Credentials management flaw in Lynxspring JENEsys BAS Bridge 1.1.8 and olderCVSS CRITICAL 9.8Priority MEDIUM 45
TI-2016-07636
CVE-2016-9363
Buffer overflow in Moxa NPortCVSS HIGH 7.3Priority MEDIUM 45
TI-2017-03265
CVE-2017-5145
Cross-site request forgery in Carlo Gavazzi VMU-C EM and VMU-C PVCVSS CRITICAL 10.0Priority MEDIUM 45
TI-2017-03266
CVE-2017-5146
Information disclosure in Carlo Gavazzi VMU-C EM and VMU-C PVCVSS HIGH 7.5Priority MEDIUM 45
TI-2017-03284
CVE-2017-5166
Information disclosure in BINOM3 Electric Power Quality MeterCVSS CRITICAL 9.8Priority MEDIUM 45
TI-2016-07612
CVE-2016-9332
Resource management flaw in Moxa SoftCMS prior to Version 1.6CVSS HIGH 7.5Priority MEDIUM 44
TI-2016-07625
CVE-2016-9349
Information disclosure in Advantech SUSIAccess Server 3.0 and priorCVSS HIGH 7.5Priority MEDIUM 43
TI-2016-07635
CVE-2016-9362
Improper authentication in WAGO Ethernet cardsCVSS CRITICAL 9.1Priority MEDIUM 43
TI-2016-07640
CVE-2016-9367
Uncontrolled resource consumption in Moxa NPortCVSS HIGH 7.5Priority MEDIUM 43
TI-2016-05027
CVE-2016-5796
Memory corruption in Fatek Automation Designer 2.1.2.2CVSS HIGH 8.8Priority MEDIUM 42
TI-2016-05034
CVE-2016-5803
Path traversal in CA Unified Infrastructure Management 8.47 and earlierCVSS HIGH 8.6Priority MEDIUM 42
TI-2016-05038
CVE-2016-5809
Cross-site request forgery in Schneider Electric IONXXXX SeriesCVSS HIGH 8.8Priority MEDIUM 42
TI-2016-06877
CVE-2016-8368
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet…CVSS HIGH 8.6Priority MEDIUM 42
TI-2016-07638
CVE-2016-9365
Cross-site request forgery in Moxa NPortCVSS HIGH 8.8Priority MEDIUM 42
TI-2017-03263
CVE-2017-5143
Path traversal in Honeywell XL Web II ControllerCVSS HIGH 8.6Priority MEDIUM 42
TI-2016-05017
CVE-2016-5782
Improper input validation in Locus Energy LGate through 320CVSS HIGH 8.6Priority MEDIUM 41
TI-2016-06870
CVE-2016-8361
Hard-coded credentials in Lynxspring JENEsys BAS Bridge 1.1.8 and olderCVSS HIGH 8.6Priority MEDIUM 41
TI-2017-03262
CVE-2017-5142
Improper privilege management in Honeywell XL Web II ControllerCVSS CRITICAL 9.1Priority MEDIUM 41
TI-2017-03268
CVE-2017-5149
NULL pointer dereference in St. Jude Merlin@home Transmitter before 8.2.2CVSS HIGH 8.9Priority MEDIUM 41
TI-2017-03285
CVE-2017-5167
Hard-coded credentials in BINOM3 Electric Power Quality MeterCVSS HIGH 8.6Priority MEDIUM 40
TI-2016-06869
CVE-2016-8360
Double free in Moxa SoftCMS prior to Version 1.6CVSS HIGH 8.1Priority LOW 39
TI-2016-06878
CVE-2016-8369
Cross-site request forgery in Lynxspring JENEsys BAS Bridge 1.1.8 and olderCVSS HIGH 8.8Priority LOW 39
TI-2016-06881
CVE-2016-8372
Credentials management flaw in Moxa ioLogik E1200 Series before 3.12CVSS HIGH 8.1Priority LOW 39
TI-2016-07614
CVE-2016-9334
An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller…CVSS HIGH 7.3Priority LOW 39
TI-2017-03286
CVE-2017-5168
Path traversal in Hanwha Techwin Smart Security Manager Versions 1.5 and priorCVSS HIGH 7.5Priority LOW 39
TI-2016-06865
CVE-2016-8356
Cross-site scripting in Kabona AB WDC prior to Version 3.4.0CVSS HIGH 8.2Priority LOW 38
TI-2016-06887
CVE-2016-8379
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik…CVSS HIGH 8.1Priority LOW 38
TI-2016-07626
CVE-2016-9351
Path traversal in Advantech SUSIAccess Server 3.0 and priorCVSS HIGH 7.0Priority LOW 38
TI-2016-07637
CVE-2016-9364
Path traversal in Fidelix FX-20 Series Controllers prior to 11.50.19CVSS HIGH 7.5Priority LOW 38
TI-2016-03396
CVE-2016-3995
The timing attack protection in Rijndael::Enc::ProcessAndXorBlock and…CVSS HIGH 7.5Priority LOW 37
TI-2016-05029
CVE-2016-5798
Memory corruption in Fatek Automation Designer 2.1.2.2CVSS HIGH 7.5Priority LOW 37
TI-2016-05036
CVE-2016-5805
Memory corruption in Delta Electronics WPLSoft, ISPSoft, and PMSoftCVSS HIGH 7.8Priority LOW 37
TI-2016-06713
CVE-2016-7987
An issue was discovered in Siemens ETA4 firmware (all versions prior to Revision 08) of…CVSS HIGH 7.5Priority LOW 37
TI-2016-06857
CVE-2016-8346
Sensitive information in log files in Moxa EDR-810 Industrial Secure RouterCVSS HIGH 7.5Priority LOW 37
TI-2016-06867
CVE-2016-8358
Origin validation error in Smiths-Medical CADD-Solis Medication Safety Software through…CVSS HIGH 8.5Priority LOW 37
TI-2016-06882
CVE-2016-8374
Uncontrolled resource consumption in Schneider Electric Magelis HMICVSS HIGH 7.5Priority LOW 37
TI-2016-08112
CVE-2016-10026
ikiwiki 3.20161219 does not properly check if a revision changes the access permissions…CVSS HIGH 7.5Priority LOW 37
TI-2017-03269
CVE-2017-5151
SQL injection in VideoInsight Web Client 6.3.5.11 and previousCVSS HIGH 7.3Priority LOW 37
TI-2016-02313
CVE-2016-2568
pkexec, when used with --user nonpriv, allows local users to escape to the parent session…CVSS HIGH 7.8Priority LOW 36
TI-2016-05018
CVE-2016-5786
Information disclosure in OmniMetrix OmniView 1.2CVSS HIGH 7.5Priority LOW 36
TI-2016-05032
CVE-2016-5801
Improper access control in OmniMetrix OmniView 1.2CVSS HIGH 7.5Priority LOW 36
TI-2016-05033
CVE-2016-5802
Out-of-bounds write in Delta Electronics WPLSoft, ISPSoft, and PMSoftCVSS HIGH 7.8Priority LOW 36
TI-2016-07000
CVE-2016-8495
Information disclosure in Fortinet FortiManagerCVSS HIGH 7.4Priority LOW 36
TI-2016-07620
CVE-2016-9344
Sensitive information in log files in Moxa MiiNePortCVSS HIGH 7.5Priority LOW 36
TI-2016-03916
CVE-2016-4547
Samsung devices with Android KK(4.4), L(5.0/5.1), or M(6.0) allow attackers to cause a…CVSS HIGH 7.5Priority LOW 35
TI-2016-06879
CVE-2016-8370
Broken or risky cryptographic algorithm in Mitsubishi Electric MELSEC-Q Series Ethernet…CVSS HIGH 7.5Priority LOW 35
TI-2017-03273
CVE-2017-5155
An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and…CVSS HIGH 7.3Priority LOW 35
TI-2017-03287
CVE-2017-5169
Cross-site request forgery in Hanwha Techwin Smart Security Manager 1.5 and priorCVSS HIGH 7.5Priority LOW 35
TI-2016-05260
CVE-2016-6129
The rsa_verify_hash_ex function in rsa_verify_hash.c in LibTomCrypt, as used in OP-TEE…CVSS HIGH 7.5Priority LOW 34
TI-2016-07038
CVE-2016-8566
Credentials management flaw in Siemens SICAM PAS before 8.00CVSS HIGH 7.8Priority LOW 34
TI-2016-07627
CVE-2016-9353
Access control flaw in Advantech SUSIAccess Server 3.0 and priorCVSS HIGH 7.8Priority LOW 34
TI-2016-07630
CVE-2016-9356
Improper access control in Moxa DACenter 1.4 and olderCVSS HIGH 7.8Priority LOW 34
TI-2016-08300
CVE-2016-10224
An issue was discovered in Sauter NovaWeb web HMI.CVSS HIGH 7.2Priority LOW 34
TI-2017-03271
CVE-2017-5153
Sensitive information in log files in OSIsoft PI Coresight and PI Web APICVSS HIGH 7.8Priority LOW 34
TI-2017-03283
CVE-2017-5165
Cross-site request forgery in BINOM3 Electric Power Quality MeterCVSS HIGH 7.6Priority LOW 34
TI-2015-07200
CVE-2015-8750
libdwarf 20151114 and earlier allows remote attackers to cause a denial of service (NULL…CVSS MEDIUM 6.5Priority LOW 33
TI-2016-06863
CVE-2016-8354
Code injection in Schneider Electric Unity PRO Control prior to V11.1CVSS HIGH 7.0Priority LOW 33
TI-2016-06866
CVE-2016-8357
Access control flaw in Lynxspring JENEsys BAS Bridge 1.1.8 and olderCVSS HIGH 7.1Priority LOW 33
TI-2016-07616
CVE-2016-9337
Command injection in Tesla Gateway ECU on Model S automobileCVSS MEDIUM 6.8Priority LOW 33
TI-2017-03279
CVE-2017-5161
Uncontrolled search path in Sielco Sistemi Winlog SCADA Software prior to Version 3.02.01CVSS HIGH 7.2Priority LOW 33
TI-2016-06871
CVE-2016-8362
Improper authentication in Moxa OnCellCVSS MEDIUM 6.5Priority LOW 32
TI-2016-06876
CVE-2016-8367
Uncontrolled resource consumption in Schneider Electric Magelis HMICVSS MEDIUM 5.3Priority LOW 31
TI-2016-07121
CVE-2016-8659
Bubblewrap before 0.1.3 sets the PR_SET_DUMPABLE flag, which might allow local users to…CVSS HIGH 7.0Priority LOW 31
TI-2017-02991
CVE-2017-3896
Improper input validation in Intel McAfee AgentCVSS MEDIUM 5.9Priority LOW 31
TI-2014-07939
CVE-2014-9760
Cross-site scripting (XSS) vulnerability in the displayLogin function in html/index.php…CVSS MEDIUM 6.1Priority LOW 30
TI-2016-06862
CVE-2016-8353
Access control flaw in OSIsoft PI Web API 2015 R2 1.5.1CVSS MEDIUM 6.4Priority LOW 30
TI-2016-06868
CVE-2016-8359
Cross-site scripting in Moxa ioLogik E1200 Series before 3.12CVSS MEDIUM 6.1Priority LOW 30
TI-2016-07621
CVE-2016-9345
Access control flaw in Emerson DeltaV Easy Security Management through 13.3CVSS MEDIUM 6.8Priority LOW 30
TI-2016-07633
CVE-2016-9360
Insufficiently protected credentials in GE Proficy HMI/SCADA iFIX, Proficy HMI/SCADA…CVSS MEDIUM 6.7Priority LOW 30
TI-2017-03275
CVE-2017-5157
Cross-site scripting in Schneider Electric homeLYnk Controller prior to V1.5.0CVSS MEDIUM 6.1Priority LOW 30
TI-2017-03281
CVE-2017-5163
Path traversal in Belden Hirschmann GECKO 2.0.00 and priorCVSS MEDIUM 5.9Priority LOW 30
TI-2016-02046
CVE-2016-2274
Cross-site scripting in Adcon Telemetry A850 Telemetry Gateway Base StationCVSS MEDIUM 6.1Priority LOW 29
TI-2016-05040
CVE-2016-5811
Cross-site scripting in Visonic PowerLink2CVSS MEDIUM 6.1Priority LOW 29
TI-2016-06860
CVE-2016-8350
Cross-site request forgery in Moxa ioLogik E1200 Series before 3.12CVSS MEDIUM 6.3Priority LOW 29
TI-2016-06884
CVE-2016-8376
Open redirect in Kabona AB WDC Vulnerabilities prior to Version 3.4.0CVSS MEDIUM 6.1Priority LOW 29
TI-2016-07643
CVE-2016-9371
Cross-site scripting in Moxa NPortCVSS MEDIUM 6.1Priority LOW 29
TI-2017-03261
CVE-2017-5141
Session fixation in Honeywell XL Web II ControllerCVSS MEDIUM 6.0Priority LOW 29
TI-2017-03282
CVE-2017-5164
Cross-site scripting in BINOM3 Electric Power Quality MeterCVSS MEDIUM 6.1Priority LOW 29
TI-2016-07631
CVE-2016-9357
Path traversal in Eaton ePDU EoL devicesCVSS MEDIUM 5.3Priority LOW 28
TI-2016-05042
CVE-2016-5813
Information disclosure in Visonic PowerLink2CVSS MEDIUM 5.3Priority LOW 27
TI-2016-07618
CVE-2016-9339
Path traversal in INTERSCHALT VDR G4e 5.220 and priorCVSS MEDIUM 5.3Priority LOW 27
TI-2016-07622
CVE-2016-9346
Cryptographic flaw in Moxa MiiNePortCVSS MEDIUM 5.3Priority LOW 27
TI-2016-07628
CVE-2016-9354
Resource management flaw in Moxa DACenter 1.4 and olderCVSS MEDIUM 5.5Priority LOW 27
TI-2017-00916
CVE-2017-1121
Cross-site scripting in IBM WebSphere Application ServerCVSS MEDIUM 5.4Priority LOW 26
TI-2017-02995
CVE-2017-3902
Cross-site scripting in Intel ePOCVSS MEDIUM 5.4Priority LOW 26
TI-2016-02329
CVE-2016-2787
The Puppet Communications Protocol in Puppet Enterprise 2015.3.x before 2015.3.3 does not…CVSS MEDIUM 5.3Priority LOW 25
TI-2016-07629
CVE-2016-9355
Credentials management flaw in BD Alaris 8015 Insufficiently Protected Credentials…CVSS MEDIUM 5.3Priority LOW 25
TI-2016-03915
CVE-2016-4546
Samsung devices with Android KK(4.4) or L(5.0/5.1) allow local users to cause a denial of…CVSS MEDIUM 5.5Priority LOW 24
TI-2016-06883
CVE-2016-8375
Credentials management flaw in BD Alaris 8015 through 9.7 and 8000CVSS MEDIUM 4.9Priority LOW 24
TI-2016-07623
CVE-2016-9347
An issue was discovered in Emerson SE4801T0X Redundant Wireless I/O Card V13.3, and…CVSS MEDIUM 5.0Priority LOW 23
TI-2016-06856
CVE-2016-8344
Improper input validation in Honeywell Experion PKS through 431CVSS LOW 3.7Priority LOW 21
TI-2016-07617
CVE-2016-9338
An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller…CVSS LOW 2.7Priority LOW 18
TI-2016-07624
CVE-2016-9348
Credentials management flaw in Moxa NPortCVSS LOW 3.3Priority LOW 16