TI-2021-08669 CVE-2021-27101 | SQL injection in Accellion FTA via crafted Host header | CVSS CRITICAL 9.8 | PriorityPriority CRITICAL 100 KEV |
TI-2021-08671 CVE-2021-27103 | Server-side request forgery in Accellion FTA via wmProgressstat.html | CVSS CRITICAL 9.8 | PriorityPriority CRITICAL 100 KEV |
TI-2021-08672 CVE-2021-27104 | OS command execution in Accellion FTA via crafted admin requests | CVSS CRITICAL 9.8 | PriorityPriority CRITICAL 100 KEV |
TI-2021-08670 CVE-2021-27102 | OS command execution in Accellion FTA through a local web service | CVSS HIGH 7.8 | PriorityPriority CRITICAL 93 KEV |
TI-2021-04415 CVE-2021-21315 | Command injection in systeminformation lets local users run commands | CVSS HIGH 7.8 | PriorityPriority CRITICAL 91 KEV |
TI-2021-06204 CVE-2021-23840 | Integer overflow in CipherUpdate | CVSS HIGH 7.5 | PriorityPriority HIGH 70 |
TI-2021-08777 CVE-2021-27236 | An issue was discovered in Mutare Voice (EVM) 3.x before 3.3.8. | CVSS CRITICAL 9.8 | PriorityPriority MEDIUM 46 |
TI-2020-15210 CVE-2020-24841 | PNPSCADA 2.200816204020 allows SQL injection via parameter 'interf' in /browse.jsp. | CVSS CRITICAL 9.8 | PriorityPriority MEDIUM 45 |
TI-2021-07781 CVE-2021-25648 | Mobile application "Testes de Codigo" 11.4 and prior allows an attacker to gain access to… | CVSS CRITICAL 9.8 | PriorityPriority MEDIUM 45 |
TI-2020-18072 CVE-2020-35565 | An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. | CVSS CRITICAL 9.8 | PriorityPriority MEDIUM 44 |
TI-2021-08770 CVE-2021-27229 | Mumble before 1.3.4 allows remote code execution if a victim navigates to a crafted URL… | CVSS HIGH 8.8 | PriorityPriority MEDIUM 44 |
TI-2021-08775 CVE-2021-27234 | An issue was discovered in Mutare Voice (EVM) 3.x before 3.3.8. | CVSS CRITICAL 9.8 | PriorityPriority MEDIUM 44 |
TI-2021-08773 CVE-2021-27232 | The RTSPLive555.dll ActiveX control in Pelco Digital Sentry Server 7.18.72.11464 has a… | CVSS HIGH 8.8 | PriorityPriority MEDIUM 42 |
TI-2021-03378 CVE-2021-20074 | OS command injection in Racom MIDGE Firmware | CVSS HIGH 8.8 | PriorityPriority MEDIUM 41 |
TI-2021-04093 CVE-2021-20987 | Hilscher: EtherNet/IP stack crash for specific CIP service | CVSS HIGH 8.6 | PriorityPriority MEDIUM 40 |
TI-2021-03377 CVE-2021-20073 | Racom's MIDGE Firmware 4.4.40.105 contains an issue that allows for cross-site request forgeries. | CVSS HIGH 8.8 | PriorityPriority LOW 39 |
TI-2021-06205 CVE-2021-23841 | Null pointer deref in X509_issuer_and_serial_hash() | CVSS MEDIUM 5.9 | PriorityPriority LOW 37 |
TI-2020-18066 CVE-2020-35558 | SSRF in products of MB connect line and Helmholz | CVSS HIGH 7.5 | PriorityPriority LOW 36 |
TI-2021-04416 CVE-2021-21316 | Arbitrary code execution in less-openui5 | CVSS HIGH 7.8 | PriorityPriority LOW 36 |
TI-2020-18071 CVE-2020-35564 | An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. | CVSS HIGH 7.5 | PriorityPriority LOW 35 |
TI-2021-03376 CVE-2021-20072 | Path traversal in Racom MIDGE Firmware | CVSS HIGH 7.2 | PriorityPriority LOW 35 |
TI-2021-04092 CVE-2021-20986 | Hilscher: Denial of Service vulnerability in PROFINET IO Device | CVSS HIGH 7.5 | PriorityPriority LOW 35 |
TI-2020-09336 CVE-2020-11635 | The Zscaler Client Connector prior to 3.1.0 did not sufficiently validate RPC clients… | CVSS HIGH 7.8 | PriorityPriority LOW 34 |
TI-2020-18074 CVE-2020-35567 | An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. | CVSS HIGH 7.8 | PriorityPriority LOW 34 |
TI-2021-03379 CVE-2021-20075 | Racom's MIDGE Firmware 4.4.40.105 contains an issue that allows for privilege escalation via configd. | CVSS HIGH 7.8 | PriorityPriority LOW 34 |
TI-2020-18065 CVE-2020-35557 | Improper Access Validation in products of MB connect line and Helmholz | CVSS MEDIUM 6.5 | PriorityPriority LOW 31 |
TI-2021-04417 CVE-2021-21317 | Denial of Service in uap-core | CVSS MEDIUM 5.3 | PriorityPriority LOW 29 |
TI-2020-17531 CVE-2020-29025 | DOM-based Javascript injection | CVSS MEDIUM 6.1 | PriorityPriority LOW 28 |
TI-2020-18068 CVE-2020-35560 | An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. | CVSS MEDIUM 6.1 | PriorityPriority LOW 28 |
TI-2020-18076 CVE-2020-35569 | An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. | CVSS MEDIUM 6.1 | PriorityPriority LOW 28 |
TI-2021-03370 CVE-2021-20066 | JSDom improperly allows the loading of local resources, which allows for local files to… | CVSS MEDIUM 5.6 | PriorityPriority LOW 28 |
TI-2020-18069 CVE-2020-35561 | SSRF in variuos products of MB connect line and Helmholz | CVSS MEDIUM 5.3 | PriorityPriority LOW 27 |
TI-2020-18073 CVE-2020-35566 | Local file inclusion vulnerability in products of MB connect line and Helmholz | CVSS MEDIUM 5.3 | PriorityPriority LOW 27 |
TI-2020-18077 CVE-2020-35570 | Foreced Browsing vulnerability in products of MB connect line and Helmholz | CVSS MEDIUM 5.3 | PriorityPriority LOW 27 |
TI-2021-08772 CVE-2021-27231 | Hestia Control Panel 1.3.5 and below, in a shared-hosting environment, sometimes allows… | CVSS MEDIUM 5.4 | PriorityPriority LOW 27 |
TI-2020-17451 CVE-2020-28918 | DualShield 5.9.8.0821 allows username enumeration on its login form. | CVSS MEDIUM 5.3 | PriorityPriority LOW 26 |
TI-2020-17528 CVE-2020-29022 | Host Header Injection allowing web cache poisoning attacks | CVSS MEDIUM 5.3 | PriorityPriority LOW 26 |
TI-2021-03371 CVE-2021-20067 | Missing authentication in Racom MIDGE Firmware | CVSS MEDIUM 5.3 | PriorityPriority LOW 26 |
TI-2020-15523 CVE-2020-25340 | An issue was discovered in NFStream 5.2.0. | CVSS MEDIUM 5.5 | PriorityPriority LOW 25 |
TI-2020-17530 CVE-2020-29024 | Missing HtppOnly and Secure flags | CVSS MEDIUM 5.3 | PriorityPriority LOW 25 |
TI-2020-17533 CVE-2020-29027 | Reflected cross site scripting in Secomea SiteManager | CVSS MEDIUM 5.4 | PriorityPriority LOW 25 |
TI-2020-18070 CVE-2020-35563 | An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. | CVSS MEDIUM 5.4 | PriorityPriority LOW 25 |
TI-2021-08748 CVE-2021-27203 | In Dekart Private Disk 2.15, invalid use of the Type3 user buffer for IOCTL codes using… | CVSS MEDIUM 5.5 | PriorityPriority LOW 25 |
TI-2021-08776 CVE-2021-27235 | An issue was discovered in Mutare Voice (EVM) 3.x before 3.3.8. | CVSS MEDIUM 4.9 | PriorityPriority LOW 24 |
TI-2021-08778 CVE-2021-27237 | The admin panel in BlackCat CMS 1.3.6 allows stored XSS (by an admin) via the Display… | CVSS MEDIUM 4.8 | PriorityPriority LOW 24 |
TI-2021-03372 CVE-2021-20068 | Cross-site scripting in Racom MIDGE Firmware | CVSS MEDIUM 4.8 | PriorityPriority LOW 23 |
TI-2021-03373 CVE-2021-20069 | Cross-site scripting in Racom MIDGE Firmware | CVSS MEDIUM 4.8 | PriorityPriority LOW 23 |
TI-2021-03374 CVE-2021-20070 | Cross-site scripting in Racom MIDGE Firmware | CVSS MEDIUM 4.8 | PriorityPriority LOW 23 |
TI-2021-03375 CVE-2021-20071 | Cross-site scripting in Racom MIDGE Firmware | CVSS MEDIUM 4.8 | PriorityPriority LOW 23 |
TI-2021-06203 CVE-2021-23839 | Incorrect SSLv2 rollback protection | CVSS LOW 3.7 | PriorityPriority LOW 23 |
TI-2021-08774 CVE-2021-27233 | An issue was discovered in Mutare Voice (EVM) 3.x before 3.3.8. | CVSS MEDIUM 4.9 | PriorityPriority LOW 23 |
TI-2020-18067 CVE-2020-35559 | An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. | CVSS MEDIUM 4.3 | PriorityPriority LOW 22 |
TI-2020-18075 CVE-2020-35568 | Sensitive Information Exposure in products of MB connect line and Helmholz | CVSS MEDIUM 4.3 | PriorityPriority LOW 22 |
TI-2020-17691 CVE-2020-29457 | A Privilege Elevation vulnerability in OPC UA .NET Standard Stack 1.4.363.107 could allow… | CVSS MEDIUM 4.4 | PriorityPriority LOW 20 |
TI-2020-17529 CVE-2020-29023 | CSV Formula Injection possible due to improper fields escaping in GateManager | CVSS LOW 3.5 | PriorityPriority LOW 18 |