Priority LOW 30
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering works…
CVSS 3.1HIGH 7.1· Local · Low privileges · No interaction · EPSS 0.00149 · Published 2024-02-14 · Fixed in v16.0, v2023 CWE-522
Priority LOW 37
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when condu…
CVSS 3.1HIGH 8.1· Network · No auth · No interaction · EPSS 0.00317 · Published 2024-02-14 · Fixed in v16.0, v2023 CWE-924
Priority LOW 35
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to a project file protected with application password when opening the file with EcoStruxure Control Expert.
CVSS 3.1HIGH 7.7· Local · No auth · No interaction · EPSS 0.0023 · Published 2024-02-14 · Fixed in v16.0, v2023 CWE-798
Priority LOW 24
A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert.
CVSS 3.1MEDIUM 5.5· Local · Low privileges · No interaction · EPSS 0.00146 · Published 2023-04-18 · No fix listed CWE-269
Priority MEDIUM 42
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints.
CVSS 3.1HIGH 8.8· Network · No auth · User interaction · EPSS 0.00845 · Published 2023-04-18 · No fix listed CWE-668
Priority MEDIUM 46
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01455 · Published 2023-01-31 · No fix listed CWE-294
Priority MEDIUM 45
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is l…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01173 · Published 2023-01-30 · No fix listed CWE-754
Priority LOW 24
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened.
CVSS 3.1MEDIUM 5.5· Local · No auth · User interaction · EPSS 0.00198 · Published 2022-09-13 · No fix listed CWE-119
Priority MEDIUM 43
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00785 · Published 2022-09-12 · No fix listed CWE-640
Priority MEDIUM 47
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.02423 · Published 2022-04-14 · No fix listed CWE-787
Priority MEDIUM 56
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution o…
CVSS 3.1HIGH 7.8· Local · No auth · User interaction · EPSS 0.261 · Published 2022-03-28 · Fixed in V15.0 SP1, 2020 CWE-22
Priority LOW 28
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to…
CVSS 3.1MEDIUM 5.9· Network · No auth · No interaction · EPSS 0.0086 · Published 2022-03-09 · No fix listed CWE-754
Priority LOW 27
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an a…
CVSS 3.1MEDIUM 5.9· Network · No auth · No interaction · EPSS 0.00644 · Published 2022-03-09 · No fix listed CWE-119
Priority LOW 24
Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers…
CVSS 3.1MEDIUM 5.5· Local · Low privileges · No interaction · EPSS 0.00109 · Published 2021-07-14 · No fix listed CWE-311
Priority LOW 24
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers…
CVSS 3.1MEDIUM 5.5· Local · Low privileges · No interaction · EPSS 0.00236 · Published 2021-07-14 · No fix listed CWE-522
Priority LOW 31
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers…
CVSS 3.1HIGH 7.1· Local · Low privileges · No interaction · EPSS 0.00217 · Published 2021-07-14 · No fix listed CWE-522
Priority MEDIUM 47
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Exper…
CVSS 3.1CRITICAL 9.1· Network · No auth · No interaction · EPSS 0.01051 · Published 2021-07-14 · No fix listed CWE-290
Priority LOW 31
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers…
CVSS 3.1HIGH 7.1· Local · Low privileges · No interaction · EPSS 0.00216 · Published 2021-07-14 · No fix listed CWE-522
Priority MEDIUM 40
A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software…
CVSS 3.1HIGH 8.6· Local · No auth · User interaction · EPSS 0.01447 · Published 2020-12-11 · No fix listed CWE-123
Priority LOW 37
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC si…
CVSS 3.1HIGH 7.5· Network · No auth · No interaction · EPSS 0.01905 · Published 2020-11-19 · No fix listed CWE-120
Priority LOW 35
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in…
CVSS 3.1HIGH 7.5· Network · No auth · No interaction · EPSS 0.01288 · Published 2020-11-19 · No fix listed CWE-754
Priority MEDIUM 40
A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending special…
CVSS 3.1HIGH 8.8· Network · Low privileges · No interaction · EPSS 0.01178 · Published 2020-11-19 · No fix listed CWE-494
Priority MEDIUM 47
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution whe…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.02757 · Published 2020-11-19 · No fix listed CWE-307
Priority LOW 34
A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.
CVSS 3.1HIGH 7.8· Local · Low privileges · No interaction · EPSS 0.00327 · Published 2020-11-19 · No fix listed CWE-863
Priority MEDIUM 45
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01581 · Published 2020-03-23 · No fix listed CWE-74