Priority LOW 31

Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal.​

CVSS 3.1MEDIUM 6.8 Physical No auth No interaction EPSS 0.00157 Published 2026-05-07 Fixed in February 25, 2026 CWE-1263
Priority LOW 15

Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user information to submit web requests to an API endpoint that would…

CVSS 3.1LOW 3.1 Network Low privileges No interaction EPSS 0.00198 Published 2025-12-04 Fixed in December 4, 2025 CWE-639
Priority LOW 18

Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view plaintext passwords from errors logged under certain circumstances.

CVSS 3.1MEDIUM 4.1 Local High privileges No interaction EPSS 0.00117 Published 2025-12-04 Fixed in December 4, 2025 CWE-532
Priority MEDIUM 43

Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances.

CVSS 3.1CRITICAL 9.8 Network No auth No interaction EPSS 0.00358 Published 2025-12-04 Fixed in December 4, 2025 CWE-307
Priority LOW 32

Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality.

CVSS 3.1MEDIUM 6.8 Physical No auth No interaction EPSS 0.00305 Published 2025-07-24 Fixed in June 25, 2025 CWE-258
Priority LOW 31

Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files.

CVSS 3.1MEDIUM 6.8 Physical No auth No interaction EPSS 0.00215 Published 2025-07-24 Fixed in June 25, 2025 CWE-312
Priority LOW 30

Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges.

CVSS 3.1MEDIUM 6.5 Local Low privileges No interaction EPSS 0.00194 Published 2025-07-24 Fixed in June 25, 2025 CWE-502
Priority HIGH 72

Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Pacea…

CVSS 3.1CRITICAL 9.8 Network No auth No interaction EPSS 0.28495 Published 2023-06-29 No fix listed CWE-502
Priority LOW 30

Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requires a security update to fix.

CVSS 3.1MEDIUM 6.8 Physical No auth No interaction EPSS 0.00266 Published 2023-03-01 Fixed in A51200, A51300 CWE-620
Priority LOW 22

A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components.

CVSS 3.1MEDIUM 4.8 Adjacent network Low privileges No interaction EPSS 0.00345 Published 2022-11-17 No fix listed CWE-693
Priority MEDIUM 45

Medtronic MyCareLink Smart 25000 is vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be uploaded and executed on the Patient Reader.

CVSS 3.1HIGH 8.8 Adjacent network No auth User interaction EPSS 0.0384 Published 2020-12-14 No fix listed CWE-367
Priority MEDIUM 49

Medtronic MyCareLink Smart 25000 is vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart Patient Reader software sta…

CVSS 3.1CRITICAL 9.8 Network No auth No interaction EPSS 0.03931 Published 2020-12-14 No fix listed CWE-122
Priority LOW 39

Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to…

CVSS 3.1HIGH 8.8 Adjacent network No auth No interaction EPSS 0.00796 Published 2020-12-14 No fix listed CWE-287
Priority LOW 22

In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the…

CVSS 3.1MEDIUM 4.8 Physical No auth No interaction EPSS 0.00388 Published 2019-11-08 No fix listed CWE-287
Priority LOW 21

In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the…

CVSS 3.1MEDIUM 4.6 Physical No auth No interaction EPSS 0.00366 Published 2019-11-08 No fix listed CWE-693
Priority LOW 34

Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use th…

CVSS 3.1HIGH 7.8 Local Low privileges No interaction EPSS 0.00268 Published 2019-11-08 No fix listed CWE-328
Priority LOW 37

Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use mu…

CVSS 3.1HIGH 7.5 Network No auth No interaction EPSS 0.02011 Published 2019-11-08 No fix listed CWE-798
Priority LOW 28

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Co…

CVSS 3.1MEDIUM 6.5 Adjacent network No auth No interaction EPSS 0.00195 Published 2019-03-26 No fix listed CWE-319
Priority MEDIUM 42

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Co…

CVSS 3.1CRITICAL 9.3 Adjacent network No auth No interaction EPSS 0.00895 Published 2019-03-25 No fix listed CWE-284