Priority HIGH 82
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to conta…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00838 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a s…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.0085 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand functi…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00851 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the dev…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00838 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to c…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00838 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00928 · Published 2023-07-14 · No fix listed CWE-787
Priority HIGH 82
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00928 · Published 2023-07-14 · No fix listed CWE-787
Priority HIGH 82
Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01153 · Published 2023-07-10 · No fix listed CWE-787
Priority HIGH 82
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01153 · Published 2023-07-10 · No fix listed CWE-787
Priority HIGH 82
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01153 · Published 2023-07-10 · No fix listed CWE-787
Priority HIGH 81
A vulnerability was found in Tenda AC1206 15.03.06.23.
CVSS 4.0CRITICAL 9.3· Network · No auth · No interaction · EPSS 0.01579 · Published 2025-09-15 · No fix listed CWE-119
Priority HIGH 81
A vulnerability was detected in Tenda AC1206 15.03.06.23.
CVSS 4.0CRITICAL 9.3· Network · No auth · No interaction · EPSS 0.01155 · Published 2025-08-27 · No fix listed CWE-119
Priority HIGH 73
A vulnerability was found in Tenda AC1206 15.03.06.23.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.01751 · Published 2025-07-13 · No fix listed CWE-119
Priority HIGH 73
A vulnerability was found in Tenda AC1206 up to 15.03.06.23.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.00918 · Published 2025-05-06 · No fix listed CWE-119
Priority HIGH 73
A vulnerability was found in Tenda AC1206 up to 15.03.06.23.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.01177 · Published 2025-05-05 · No fix listed CWE-119
Priority HIGH 73
A vulnerability was found in Tenda AC1206 15.03.06.23.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.07635 · Published 2025-04-07 · No fix listed CWE-119
Priority HIGH 73
A vulnerability was found in Tenda AC1206 up to 20241027.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.01297 · Published 2024-10-28 · No fix listed CWE-121
Priority MEDIUM 64
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022.
CVSS 4.0HIGH 7.1· Network · Low privileges · No interaction · EPSS 0.00805 · Published 2024-10-23 · No fix listed CWE-476
Priority MEDIUM 57
A vulnerability was determined in Tenda AC1206 15.03.06.23.
CVSS 4.0MEDIUM 5.3· Network · Low privileges · No interaction · EPSS 0.09413 · Published 2026-01-05 · No fix listed CWE-74
Priority MEDIUM 57
A vulnerability classified as critical was found in Tenda AC1206 up to 15.03.06.23.
CVSS 4.0MEDIUM 5.3· Network · Low privileges · No interaction · EPSS 0.23111 · Published 2024-10-10 · No fix listed CWE-77
Priority MEDIUM 47
Tenda AC1206 V15.03.06.23 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.02462 · Published 2022-08-25 · No fix listed CWE-78
Priority MEDIUM 44
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function fromSetIpMacBind.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.012 · Published 2022-08-25 · No fix listed CWE-787
Priority MEDIUM 44
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the PPPOEPassword parameter in the function formQuickIndex.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.012 · Published 2022-08-25 · No fix listed CWE-787
Priority MEDIUM 44
Tenda AC1206 V15.03.06.23 was discovered to contain multiple stack overflows via the deviceMac and the device_id parameters in the function addWifiMacFilter.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.012 · Published 2022-08-25 · No fix listed CWE-787
Priority MEDIUM 44
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function fromSetSysTime.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.012 · Published 2022-08-25 · No fix listed CWE-787
Load more