Priority HIGH 82
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to conta…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00838 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a s…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.0085 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand functi…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00851 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the dev…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00838 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to c…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00838 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter func…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00838 · Published 2023-08-07 · No fix listed CWE-787
Priority HIGH 82
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00928 · Published 2023-07-14 · No fix listed CWE-787
Priority HIGH 82
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00928 · Published 2023-07-14 · No fix listed CWE-787
Priority HIGH 82
Tenda AC5 router V15.03.06.28 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01998 · Published 2023-05-16 · No fix listed
Priority HIGH 73
A vulnerability was determined in Tenda AC5 15.03.06.47.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.0265 · Published 2026-03-27 · No fix listed CWE-119
Priority HIGH 73
A vulnerability was found in Tenda AC5 15.03.06.47.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.00644 · Published 2026-03-26 · No fix listed CWE-119
Priority HIGH 73
A vulnerability has been found in Tenda AC5 15.03.06.47.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.00759 · Published 2026-03-26 · No fix listed CWE-119
Priority HIGH 73
A flaw has been found in Tenda AC5 15.03.06.47.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.05671 · Published 2026-03-26 · No fix listed CWE-119
Priority HIGH 73
A vulnerability was detected in Tenda AC5 15.03.06.47.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.00644 · Published 2026-03-26 · No fix listed CWE-119
Priority HIGH 73
A vulnerability was found in Tenda AC5 15.03.06.47.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.01108 · Published 2025-06-09 · No fix listed CWE-119
Priority HIGH 73
A vulnerability, which was classified as critical, was found in Tenda AC5 1.0/15.03.06.47.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.0106 · Published 2025-06-06 · No fix listed CWE-119
Priority HIGH 73
A vulnerability, which was classified as critical, has been found in Tenda AC5 15.03.06.47.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.0106 · Published 2025-06-06 · No fix listed CWE-119
Priority HIGH 71
A vulnerability was found in Tenda AC5 15.03.06.47 and classified as critical.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.01018 · Published 2025-06-30 · No fix listed CWE-119
Priority HIGH 71
A vulnerability has been found in Tenda AC5 15.03.06.47 and classified as critical.
CVSS 4.0HIGH 8.7· Network · Low privileges · No interaction · EPSS 0.00984 · Published 2025-06-30 · No fix listed CWE-119
Priority MEDIUM 51
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01121 · Published 2023-08-30 · No fix listed CWE-787
Priority MEDIUM 51
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the add_white_node function.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00959 · Published 2023-04-07 · No fix listed CWE-787
Priority MEDIUM 51
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the form_fast_setting_wifi_set function.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00959 · Published 2023-04-07 · No fix listed CWE-787
Priority MEDIUM 50
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00838 · Published 2023-08-30 · No fix listed CWE-787
Priority MEDIUM 50
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00838 · Published 2023-08-30 · No fix listed CWE-787
Priority MEDIUM 50
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.00838 · Published 2023-08-30 · No fix listed CWE-787
Load more