Incorrect permission assignment in Baxter Sigma Spectrum Infusion Pumps

Priority MEDIUM 43CWE-732Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
High · Low · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits temporary configuration changes to network settings of the WBM, and allows the WBM to be rebooted. Temporary configuration changes to network settings are removed upon reboot.

Why it matters now

EPSS 0.01406 72nd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—Baxter Sigma Spectrum Infusion PumpsSigma Spectrum v6.x model 35700BAX, Baxter Spectrum v8.x model 35700BAX2,Sigma Spectrum v6.x with Wireless Battery Module v9,11,13,14,15,16,v20D29,v20D30,v20D31,v22D24, Baxter Spectrum v8.x with Wireless Battery Module v17,v20D29,v20D30,v20D31,v22D24,Baxter Spectrum Wireless Battery Module v17,v20D29,v20D30,v20D31,v22D24,Baxter Spectrum LVP v8.x w/Wireless Battery Module v17,v20D29,v20D30,v20D31,v22D24—No fix listedCNA
  • Baxter Sigma Spectrum Infusion Pumps Vendor— Affected Sigma Spectrum v6.x model 35700BAX, Baxter Spectrum v8.x model 35700BAX2,Sigma Spectrum v6.x with Wireless Battery Module v9,11,13,14,15,16,v20D29,v20D30,v20D31,v22D24, Baxter Spectrum v8.x with Wireless Battery Module v17,v20D29,v20D30,v20D31,v22D24,Baxter Spectrum Wireless Battery Module v17,v20D29,v20D30,v20D31,v22D24,Baxter Spectrum LVP v8.x w/Wireless Battery Module v17,v20D29,v20D30,v20D31,v22D24 Fixed in — No fix listed CNA

CPE configurations NVD · 7

CPEVersionsRoleVendor
cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:8.0:*:*:*:*:*:*:*8.0VulnerableBaxter
cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:*not specified by NVDRunning onBaxter
cpe:2.3:h:baxter:wireless_battery_module:17:*:*:*:*:*:*:*17Running onBaxter
cpe:2.3:h:baxter:wireless_battery_module:20d29:*:*:*:*:*:*:*20d29Running onBaxter
cpe:2.3:h:baxter:wireless_battery_module:20d30:*:*:*:*:*:*:*20d30Running onBaxter
cpe:2.3:h:baxter:wireless_battery_module:20d31:*:*:*:*:*:*:*20d31Running onBaxter
cpe:2.3:h:baxter:wireless_battery_module:22d24:*:*:*:*:*:*:*22d24Running onBaxter
  • cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:8.0:*:*:*:*:*:*:* Versions 8.0 Vulnerable ·Baxter
  • cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Baxter
  • cpe:2.3:h:baxter:wireless_battery_module:17:*:*:*:*:*:*:* Versions 17 Running on ·Baxter
  • cpe:2.3:h:baxter:wireless_battery_module:20d29:*:*:*:*:*:*:* Versions 20d29 Running on ·Baxter
  • cpe:2.3:h:baxter:wireless_battery_module:20d30:*:*:*:*:*:*:* Versions 20d30 Running on ·Baxter
  • cpe:2.3:h:baxter:wireless_battery_module:20d31:*:*:*:*:*:*:* Versions 20d31 Running on ·Baxter
  • cpe:2.3:h:baxter:wireless_battery_module:22d24:*:*:*:*:*:*:* Versions 22d24 Running on ·Baxter

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2020-12041
  2. 2026-10-03 Alias added: GHSA-gvrr-pwvw-5j3q

References

  • TI-2014-04431 Improper authentication in Baxter SIGMA Spectrum Infusion System CVSS 3.0CRITICAL 9.8
  • TI-2020-09702 The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for… CVSS 3.1CRITICAL 9.8
  • TI-2014-04432 Cleartext storage of sensitive information in Baxter SIGMA Spectrum Infusion System CVSS 3.0CRITICAL 9.8
  • TI-2020-09705 Hard-coded credentials in Baxter Sigma Spectrum Infusion Pumps CVSS 3.1CRITICAL 9.8
  • TI-2020-09703 Hard-coded credentials in Baxter Sigma Spectrum Infusion Pumps CVSS 3.1CRITICAL 9.8
  • TI-2014-04433 Hard-coded credentials in Baxter SIGMA Spectrum Infusion System CVSS 3.0CRITICAL 9.8
See all 9 →

Sources