Read the docs
TI-2022-17783 Aliases CVE-2022-38069GHSA-x446-rh2f-5gh9

Hard-coded credentials in Contec Health CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor

Priority LOW 27CWE-798Published · Updated

Key facts

Attack vector
Physical
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-798.

Summary

Multiple globally default credentials exist across all CMS8000 devices, that once exposed, allow a threat actor with momentary physical access to gain privileged access to any device. Privileged credential access enables the extraction of sensitive patient information or modification of device parameters

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.0034 27th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Contec HealthCMS8000 CONTEC ICU CCU Vital Signs Patient MonitorAll—No fix listedCNA
  • CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor VendorContec Health Affected All Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:contechealth:cms8000_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableContec Health
cpe:2.3:h:contechealth:cms8000:-:*:*:*:*:*:*:*not specified by NVDRunning onContec Health
  • cpe:2.3:o:contechealth:cms8000_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Contec Health
  • cpe:2.3:h:contechealth:cms8000:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Contec Health

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-38069
  2. 2026-10-03 Alias added: GHSA-x446-rh2f-5gh9

References

  • TI-2022-17808 Uncontrolled resource consumption in Contec Health CMS8000 CONTEC ICU CCU Vital Signs… CVSS 3.1HIGH 7.5
  • TI-2022-16724 Improper access control in Contec Health CMS8000 CONTEC ICU CCU Vital Signs Patient… CVSS 3.1MEDIUM 6.8
  • TI-2022-02790 Improper access control in Contec Health CMS8000 CONTEC ICU CCU Vital Signs Patient… CVSS 3.1MEDIUM 5.7
  • TI-2022-18078 Multiple binary application files on the CMS8000 device are compiled with 'not stripped'… CVSS 3.1MEDIUM 4.4

Sources