Read the docs
TI-2022-23857 Aliases CVE-2022-48221GHSA-699h-74gf-wcvm

An issue was discovered in Acuant AcuFill SDK before 10.22.02.03.

Priority LOW 35CWE-362Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
High
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. Multiple MSI's get executed out of a standard-user writable directory. Through a race condition and OpLock manipulation, these files can be overwritten by a standard user. They then get executed by the elevated installer. This gives a standard user full SYSTEM code execution (elevation of privileges).

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00507 43rd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:gbgplc:acuant_acufill_sdk:*:*:*:*:*:*:*:*before 10.22.02.03VulnerableGbgplc
  • cpe:2.3:a:gbgplc:acuant_acufill_sdk:*:*:*:*:*:*:*:* Versions before 10.22.02.03 Vulnerable ·Gbgplc

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-48221
  2. 2026-10-03 Alias added: GHSA-699h-74gf-wcvm

References

  • TI-2022-23862 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 8.4
  • TI-2022-23858 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 7.8
  • TI-2022-23861 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 7.3
  • TI-2022-23860 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 7.3
  • TI-2022-23859 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1MEDIUM 6.7

Sources