Read the docs
TI-2022-23858 Aliases CVE-2022-48222GHSA-7pr2-3fc2-f47w

An issue was discovered in Acuant AcuFill SDK before 10.22.02.03.

Priority LOW 35CWE-427Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-427.

Summary

An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. During SDK installation, certutil.exe is called by the Acuant installer to install certificates. This window is not hidden, and is running with elevated privileges. A standard user can break out of this window, obtaining a full SYSTEM command prompt window. This results in complete compromise via arbitrary SYSTEM code execution (elevation of privileges).

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00135 2nd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:gbgplc:acuant_acufill_sdk:*:*:*:*:*:*:*:*before 10.22.02.03VulnerableGbgplc
  • cpe:2.3:a:gbgplc:acuant_acufill_sdk:*:*:*:*:*:*:*:* Versions before 10.22.02.03 Vulnerable ·Gbgplc

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-48222
  2. 2026-10-03 Alias added: GHSA-7pr2-3fc2-f47w

References

  • TI-2022-23862 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 8.4
  • TI-2022-23857 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 7.5
  • TI-2022-23861 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 7.3
  • TI-2022-23860 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 7.3
  • TI-2022-23859 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1MEDIUM 6.7

Sources