Read the docs
TI-2022-23861 Aliases CVE-2022-48225GHSA-9p85-c2hf-rxr2

An issue was discovered in Acuant AcuFill SDK before 10.22.02.03.

Priority LOW 33CWE-427Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
Required
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-427.

Summary

An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. It is used to install drivers from several different vendors. The Gemalto Document Reader child installation process is vulnerable to DLL hijacking, because it attempts to execute (with elevated privileges) multiple non-existent DLLs out of a non-existent standard-user writable location.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00199 9th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:gbgplc:acuant_acufill_sdk:*:*:*:*:*:*:*:*before 10.22.02.03VulnerableGbgplc
  • cpe:2.3:a:gbgplc:acuant_acufill_sdk:*:*:*:*:*:*:*:* Versions before 10.22.02.03 Vulnerable ·Gbgplc

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-48225
  2. 2026-10-03 Alias added: GHSA-9p85-c2hf-rxr2

References

  • TI-2022-23862 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 8.4
  • TI-2022-23858 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 7.8
  • TI-2022-23857 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 7.5
  • TI-2022-23860 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 7.3
  • TI-2022-23859 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1MEDIUM 6.7

Sources