Read the docs
TI-2022-23862 Aliases CVE-2022-48226GHSA-g8h8-pg73-gcw3

An issue was discovered in Acuant AcuFill SDK before 10.22.02.03.

Priority LOW 38CWE-269Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Privilege escalation
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CISA ADP. Fix status from CNA. Impact type from CWE-269.

Summary

An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. During installation, an EXE gets executed out of C:\Windows\Temp. A standard user can create the path file ahead of time and obtain elevated code execution. Permissions need to be modified to prevent manipulation.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00182 7th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:gbgplc:acuant_acufill_sdk:*:*:*:*:*:*:*:*before 10.22.02.03VulnerableGbgplc
  • cpe:2.3:a:gbgplc:acuant_acufill_sdk:*:*:*:*:*:*:*:* Versions before 10.22.02.03 Vulnerable ·Gbgplc

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-48226
  2. 2026-10-03 Alias added: GHSA-g8h8-pg73-gcw3

References

  • TI-2022-23858 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 7.8
  • TI-2022-23857 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 7.5
  • TI-2022-23861 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 7.3
  • TI-2022-23860 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1HIGH 7.3
  • TI-2022-23859 An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. CVSS 3.1MEDIUM 6.7

Sources