Authenticated command injection via <redacted>.exe <redacted> parameter
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Privilege escalation, Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-250 and CWE-78.
Summary
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
Remediation
- Fix · CNA Iocharger firmware for AC models (Iocharger) Fixed in 24120701
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Iocharger firmware for AC models 24120701
11 records Highest priority Priority MEDIUM 8 MEDIUM, 3 LOW
Other records, highest priority first
- TI-2024-29275 OS command injection in Iocharger firmware for AC modelsPriority MEDIUM 46
- TI-2024-29273 OS command injection in Iocharger firmware for AC modelsPriority MEDIUM 46
- TI-2024-29271 Authenticated command injection via <redacted>.exe <redacted> parameterPriority MEDIUM 46
Timeline
- 2026-10-02 Threatist record created from CVE-2024-43648
- 2026-10-03 Alias added: GHSA-r3r4-jc6c-965m
References
More Iocharger vulnerabilities
- TI-2024-29276 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
- TI-2024-29275 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
- TI-2024-29274 OS command injection in Iocharger firmware for AC chargers CVSS 4.0CRITICAL 9.3
- TI-2024-29273 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
- TI-2024-29271 Authenticated command injection via <redacted>.exe <redacted> parameter CVSS 4.0CRITICAL 9.3
- TI-2024-29279 Unrestricted file upload in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
Sources
- CVE-2024-43648 · CVE Program
- CVE-2024-43648 · NVD
- FIRST EPSS
- GHSA-r3r4-jc6c-965m · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences