Read the docs
TI-2024-29279 Aliases CVE-2024-43657GHSA-2722-p93p-vrgm

Unrestricted file upload in Iocharger firmware for AC models

Priority MEDIUM 45CWE-434Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-434.

Summary

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.01508 74th percentileScored 2026-11-07
Fix Fixed Iocharger firmware for AC models (Iocharger): 2024120701

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
IochargerIocharger firmware for AC modelsbefore 20241207012024120701Patch availableCNA
  • Iocharger firmware for AC models VendorIocharger Affected before 2024120701 Fixed in 2024120701 Patch available CNA

Remediation

  • Fix · CNA Iocharger firmware for AC models (Iocharger) Fixed in 2024120701

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-43657
  2. 2026-10-03 Alias added: GHSA-2722-p93p-vrgm

References

  • TI-2024-29276 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
  • TI-2024-29275 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
  • TI-2024-29274 OS command injection in Iocharger firmware for AC chargers CVSS 4.0CRITICAL 9.3
  • TI-2024-29273 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
  • TI-2024-29271 Authenticated command injection via <redacted>.exe <redacted> parameter CVSS 4.0CRITICAL 9.3
  • TI-2024-29270 Authenticated command injection via <redacted>.exe <redacted> parameter CVSS 4.0CRITICAL 9.3
See all 15 →