Authenticated command injection via <redacted>.exe <redacted> parameter
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Privilege escalation, Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-250 and CWE-78.
Summary
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
Remediation
- Fix · CNA Iocharger firmware for AC models (Iocharger) Fixed in 24120701
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Iocharger firmware for AC models 24120701
11 records Highest priority Priority MEDIUM 8 MEDIUM, 3 LOW
Other records, highest priority first
- TI-2024-29275 OS command injection in Iocharger firmware for AC modelsPriority MEDIUM 46
- TI-2024-29273 OS command injection in Iocharger firmware for AC modelsPriority MEDIUM 46
- TI-2024-29270 Authenticated command injection via <redacted>.exe <redacted> parameterPriority MEDIUM 46
Timeline
- 2026-10-02 Threatist record created from CVE-2024-43649
- 2026-10-03 Alias added: GHSA-3wph-r629-c94g
References
More Iocharger vulnerabilities
- TI-2024-29276 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
- TI-2024-29275 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
- TI-2024-29274 OS command injection in Iocharger firmware for AC chargers CVSS 4.0CRITICAL 9.3
- TI-2024-29273 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
- TI-2024-29270 Authenticated command injection via <redacted>.exe <redacted> parameter CVSS 4.0CRITICAL 9.3
- TI-2024-29279 Unrestricted file upload in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
Sources
- CVE-2024-43649 · CVE Program
- CVE-2024-43649 · NVD
- FIRST EPSS
- GHSA-3wph-r629-c94g · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences