OS command injection in Iocharger firmware for AC models
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Privilege escalation, Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-250 and CWE-78.
Summary
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
Remediation
- Fix · CNA Iocharger firmware for AC models (Iocharger) Fixed in 25010801
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Iocharger firmware for AC models 25010801
3 records Highest priority Priority MEDIUM 2 MEDIUM, 1 LOW
Other records, highest priority first
- TI-2024-29281 Plaintext default credentials in firmwarePriority MEDIUM 40
- TI-2024-29280 Using the <redacted> action or <redacted>.sh script, arbitrary files and directories can…Priority LOW 32
Timeline
- 2026-10-02 Threatist record created from CVE-2024-43654
- 2026-10-03 Alias added: GHSA-938g-xvcv-qg4g
References
More Iocharger vulnerabilities
- TI-2024-29275 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
- TI-2024-29274 OS command injection in Iocharger firmware for AC chargers CVSS 4.0CRITICAL 9.3
- TI-2024-29273 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
- TI-2024-29271 Authenticated command injection via <redacted>.exe <redacted> parameter CVSS 4.0CRITICAL 9.3
- TI-2024-29270 Authenticated command injection via <redacted>.exe <redacted> parameter CVSS 4.0CRITICAL 9.3
- TI-2024-29279 Unrestricted file upload in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
Sources
- CVE-2024-43654 · CVE Program
- CVE-2024-43654 · NVD
- FIRST EPSS
- GHSA-938g-xvcv-qg4g · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences