OS command injection in Iocharger firmware for AC models
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Privilege escalation, Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-250 and CWE-78.
Summary
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
Remediation
- Fix · CNA Iocharger firmware for AC models (Iocharger) Fixed in 24120701
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Iocharger firmware for AC models 24120701
11 records Highest priority Priority MEDIUM 8 MEDIUM, 3 LOW
Other records, highest priority first
- TI-2024-29275 OS command injection in Iocharger firmware for AC modelsPriority MEDIUM 46
- TI-2024-29273 OS command injection in Iocharger firmware for AC modelsPriority MEDIUM 46
- TI-2024-29271 Authenticated command injection via <redacted>.exe <redacted> parameterPriority MEDIUM 46
Timeline
- 2026-10-02 Threatist record created from CVE-2024-43650
- 2026-10-03 Alias added: GHSA-6x4w-74f8-5jjw
References
More Iocharger vulnerabilities
- TI-2024-29276 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
- TI-2024-29275 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
- TI-2024-29274 OS command injection in Iocharger firmware for AC chargers CVSS 4.0CRITICAL 9.3
- TI-2024-29273 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
- TI-2024-29271 Authenticated command injection via <redacted>.exe <redacted> parameter CVSS 4.0CRITICAL 9.3
- TI-2024-29270 Authenticated command injection via <redacted>.exe <redacted> parameter CVSS 4.0CRITICAL 9.3
Sources
- CVE-2024-43650 · CVE Program
- CVE-2024-43650 · NVD
- FIRST EPSS
- GHSA-6x4w-74f8-5jjw · GitHub Advisory Database · CC BY 4.0