TI-2024-29281 Aliases CVE-2024-43659GHSA-qxc8-hg93-pqh7

Plaintext default credentials in firmware

Priority MEDIUM 40CWE-1391Published · Updated

Key facts

Attack vector
Local
Privileges required
High
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Information disclosure
Confidentiality · integrity · availability
High · None · None
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-256.

Summary

After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00842 58th percentileScored 2026-11-07
Fix Fixed Iocharger firmware for AC models (Iocharger): 25010801

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
IochargerIocharger firmware for AC modelsbefore 2501080125010801Patch availableCNA
  • Iocharger firmware for AC models VendorIocharger Affected before 25010801 Fixed in 25010801 Patch available CNA

Remediation

  • Fix · CNA Iocharger firmware for AC models (Iocharger) Fixed in 25010801

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Iocharger firmware for AC models 25010801

    3 records Highest priority Priority MEDIUM 2 MEDIUM, 1 LOW

    Other records, highest priority first

    • TI-2024-29276 OS command injection in Iocharger firmware for AC modelsPriority MEDIUM 46
    • TI-2024-29280 Using the <redacted> action or <redacted>.sh script, arbitrary files and directories can…Priority LOW 32

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-43659
  2. 2026-10-03 Alias added: GHSA-qxc8-hg93-pqh7

References

  • TI-2024-29276 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
  • TI-2024-29275 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
  • TI-2024-29274 OS command injection in Iocharger firmware for AC chargers CVSS 4.0CRITICAL 9.3
  • TI-2024-29273 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
  • TI-2024-29271 Authenticated command injection via <redacted>.exe <redacted> parameter CVSS 4.0CRITICAL 9.3
  • TI-2024-29270 Authenticated command injection via <redacted>.exe <redacted> parameter CVSS 4.0CRITICAL 9.3
See all 15 →

Sources