Read the docs
TI-2024-29282 Aliases CVE-2024-43660GHSA-vj9p-8pwq-8v8j

Arbitrary file download using <redacted>.sh

Priority LOW 38CWE-552Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Information disclosure
Confidentiality · integrity · availability
High · None · None
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-552.

Summary

The CGI script <redacted>.sh can be used to download any file on the filesystem. This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High, but credentials required. Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files. CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y).

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00591 48th percentileScored 2026-11-07
Fix Fixed Iocharger firmware for AC models (Iocharger): 24120701

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
IochargerIocharger firmware for AC modelsbefore 2412070124120701Patch availableCNA
  • Iocharger firmware for AC models VendorIocharger Affected before 24120701 Fixed in 24120701 Patch available CNA

Remediation

  • Fix · CNA Iocharger firmware for AC models (Iocharger) Fixed in 24120701

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Iocharger firmware for AC models 24120701

    11 records Highest priority Priority MEDIUM 8 MEDIUM, 3 LOW

    Other records, highest priority first

    • TI-2024-29275 OS command injection in Iocharger firmware for AC modelsPriority MEDIUM 46
    • TI-2024-29273 OS command injection in Iocharger firmware for AC modelsPriority MEDIUM 46
    • TI-2024-29271 Authenticated command injection via <redacted>.exe <redacted> parameterPriority MEDIUM 46

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-43660
  2. 2026-10-03 Alias added: GHSA-vj9p-8pwq-8v8j

References

  • TI-2024-29276 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
  • TI-2024-29275 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
  • TI-2024-29274 OS command injection in Iocharger firmware for AC chargers CVSS 4.0CRITICAL 9.3
  • TI-2024-29273 OS command injection in Iocharger firmware for AC models CVSS 4.0CRITICAL 9.3
  • TI-2024-29271 Authenticated command injection via <redacted>.exe <redacted> parameter CVSS 4.0CRITICAL 9.3
  • TI-2024-29270 Authenticated command injection via <redacted>.exe <redacted> parameter CVSS 4.0CRITICAL 9.3
See all 15 →

Sources