Read the docs

Privilege escalation in Octopus Deploy Octopus Server to Administrator

Priority LOW 39CWE-269Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Privilege escalation
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-269.

Summary

Octopus Deploy Octopus Server from 2019.0.0 before 2026.2.13469 and from 2026.3.0 before 2026.3.15863 is affected. Improper privilege management lets a user holding the System Manager role raise their own rights to full system Administrator. An authenticated remote attacker who holds the System Manager role can gain complete control over the server's confidentiality, integrity and availability (CWE-269).

Written with Claude Haiku 5.5 from the sources below · 2026-11-04

Description from the CNA

In affected versions of Octopus Server, a user holding the System Manager role could escalate their privileges to full system Administrator.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00229 13th percentileScored 2026-11-07
Fix Fixed Octopus Server (Octopus Deploy): 2026.2.13469, 2026.3.15863

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Octopus DeployOctopus Server2019.0.0 to before 2026.2.13469; 2026.3.0 to before 2026.3.158632026.2.13469, 2026.3.15863Patch availableCNA
  • Octopus Server VendorOctopus Deploy Affected 2019.0.0 to before 2026.2.13469; 2026.3.0 to before 2026.3.15863 Fixed in 2026.2.13469, 2026.3.15863 Patch available CNA

Remediation

Upgrade Octopus Server to version 2026.2.13469 or 2026.3.15863 or later, depending on the release line in use. The sources list no vendor advisory identifier for this fix.

Written with Claude Haiku 5.5 from the sources below · 2026-11-04

  • Fix · CNA Octopus Server (Octopus Deploy) Fixed in 2026.2.13469, 2026.3.15863

Timeline

  1. 2026-10-27 Threatist record created from CVE-2026-117466
  2. 2026-10-27 Alias added: GHSA-vg7p-mchq-388x
  3. 2026-10-28 Priority changed: MEDIUM → LOW
  4. 2026-11-04 CISA SSVC decision points changed

References

  • TI-2018-13353 In Octopus Deploy 2018.8.0 through 2018.9.x before 2018.9.1, an authenticated user with… CVSS 3.0HIGH 8.8
  • TI-2022-02375 Improper authentication in Octopus Server CVSS 3.1CRITICAL 9.8
  • TI-2022-02579 Insufficient session expiration in Octopus Server CVSS 3.1CRITICAL 9.1
  • TI-2021-11816 Deserialization of untrusted data in Octopus Deploy Halibut CVSS 3.1CRITICAL 9.8
  • TI-2018-08066 In Octopus Deploy 2018.4.4 through 2018.5.1, Octopus variables that are sourced from the… CVSS 3.0CRITICAL 9.8
  • TI-2022-02575 In affected versions of Octopus Deploy it is possible to bypass rate limiting on login using null bytes. CVSS 3.1CRITICAL 9.8
See all 117 →