Priority LOW 31
Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending…
CVSS 4.0HIGH 7.1· Adjacent network · No auth · No interaction · EPSS 0.00199 · Published 2026-06-03 · No fix listed CWE-1286
Priority LOW 35
Dräger Protector Software prior to version 6.4.2 contains a local privilege escalation vulnerability due to insecure file system permissions that allows local attackers to execute arbitrary code with elevated privileges.
CVSS 4.0HIGH 8.3· Local · No auth · User interaction · EPSS 0.00107 · Published 2026-06-02 · Fixed in 6.4.2 CWE-732
Priority LOW 35
Dräger Protector Software prior to version 6.4.2 contains a local privilege escalation vulnerability due to insecure file system permissions that allows local attackers to execute arbitrary code with elevated privileges.
CVSS 4.0HIGH 8.3· Local · No auth · User interaction · EPSS 0.00107 · Published 2026-06-02 · Fixed in 6.4.2 CWE-732
Priority LOW 32
Dräger Zeus Infinity Empowered (Zeus IE) and Zeus RS C500 anesthesia workstations contain a local security vulnerability that allows unauthorized individuals with physical access to compromise software integrity via USB…
CVSS 4.0HIGH 7.0· Physical · No auth · No interaction · EPSS 0.00169 · Published 2026-06-02 · Fixed in 1.0.5, 1.0.9 CWE-668
Priority MEDIUM 43
Dräger Core 1.0.5 and Dräger M540 Converter Service 1.0.9 contain a denial of service vulnerability that allows network-adjacent attackers to trigger high CPU load by sending specially crafted, unencrypted SDC messages d…
CVSS 4.0HIGH 8.7· Network · No auth · No interaction · EPSS 0.00284 · Published 2026-06-02 · No fix listed CWE-400
Priority MEDIUM 43
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower (with VG4.2 partially affected) contain a network message handling vulnerability that allows remote att…
CVSS 4.0HIGH 8.8· Network · No auth · No interaction · EPSS 0.0016 · Published 2026-06-02 · Fixed in VG4.2, VG4.1.1 +1 CWE-345
Priority LOW 28
Dräger Atlan A350 versions 1.00 up to and including 1.01 contains an improper input handling vulnerability that allows attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant data thr…
CVSS 4.0MEDIUM 6.3· Network · No auth · No interaction · EPSS 0.00241 · Published 2026-06-02 · No fix listed CWE-1286
Priority LOW 35
Dräger CC-Vision Basic before 7.5.3 and Dräger CC-Vision E-Cal before 7.2.5.0 contain an out-of-bounds write vulnerability when loading .gdt files.
CVSS 4.0HIGH 8.3· Local · No auth · User interaction · EPSS 0.00122 · Published 2026-06-02 · Fixed in 7.5.3, 7.2.5.0 CWE-787
Priority LOW 30
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeated…
CVSS 4.0HIGH 7.1· Adjacent network · No auth · No interaction · EPSS 0.00175 · Published 2026-06-02 · Fixed in VG3.0 CWE-400
Priority LOW 28
Dräger Perseus A500 software versions 2.00 through 2.02 contains an improper input handling vulnerability that allows external attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant…
CVSS 4.0MEDIUM 6.3· Network · No auth · No interaction · EPSS 0.00236 · Published 2026-06-02 · Fixed in 2.03 CWE-1286
Priority LOW 31
Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to co…
CVSS 4.0HIGH 7.2· Adjacent network · No auth · No interaction · EPSS 0.00193 · Published 2026-06-02 · No fix listed CWE-798
Priority LOW 30
Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by…
CVSS 4.0HIGH 7.1· Adjacent network · No auth · No interaction · EPSS 0.00187 · Published 2026-06-02 · Fixed in VG2.3.2 CWE-400
Priority MEDIUM 43
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers…
CVSS 4.0HIGH 8.8· Network · No auth · No interaction · EPSS 0.00132 · Published 2026-06-02 · Fixed in VG4.2 CWE-924
Priority LOW 23
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection.
CVSS 4.0MEDIUM 5.3· Adjacent network · No auth · No interaction · EPSS 0.00203 · Published 2026-06-02 · No fix listed CWE-538
Priority LOW 38
Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction.
CVSS 4.0HIGH 8.6· Local · No auth · No interaction · EPSS 0.00118 · Published 2026-06-01 · No fix listed CWE-451
Priority LOW 31
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet.
CVSS 4.0HIGH 7.1· Adjacent network · No auth · No interaction · EPSS 0.00413 · Published 2026-06-01 · No fix listed CWE-15
Priority LOW 24
A low privileged local attacker can abuse the affected service by using a hardcoded cryptographic key.
CVSS 3.1MEDIUM 5.5· Local · Low privileges · No interaction · EPSS 0.00136 · Published 2025-08-05 · No fix listed CWE-321
Priority LOW 35
A low privileged local attacker can interact with the affected service although user-interaction should not be allowed.
CVSS 3.1HIGH 7.8· Local · Low privileges · No interaction · EPSS 0.00137 · Published 2025-08-05 · No fix listed CWE-862
Priority MEDIUM 42
Draeger X-Dock Firmware before 03.00.13 has Active Debug Code on a debug port, leading to remote code execution by an authenticated attacker.
CVSS 3.1HIGH 8.8· Network · Low privileges · No interaction · EPSS 0.01878 · Published 2021-05-20 · No fix listed
Priority MEDIUM 44
Draeger X-Dock Firmware before 03.00.13 has Hard-Coded Credentials, leading to remote code execution by an authenticated attacker.
CVSS 3.1HIGH 8.8· Network · Low privileges · No interaction · EPSS 0.03102 · Published 2021-05-20 · No fix listed CWE-798
Priority LOW 30
Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions.
CVSS 3.0MEDIUM 6.5· Adjacent network · No auth · No interaction · EPSS 0.0078 · Published 2019-01-28 · No fix listed CWE-532
Priority LOW 30
Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions.
CVSS 3.0MEDIUM 6.5· Adjacent network · No auth · No interaction · EPSS 0.00762 · Published 2019-01-28 · No fix listed CWE-20
Priority LOW 34
Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions.
CVSS 3.0HIGH 7.8· Local · Low privileges · No interaction · EPSS 0.0039 · Published 2019-01-28 · No fix listed CWE-269